6.6.3
Cyclic Synchronous Position Mode(csp mode)
It is a position control mode to operate by creating a command position in the host
controller (master) and updating (transmitting) the command position in an
interpolation cycle.
Step 1:
Read (Position Actual Value: 6064h) and write to (Target position: 607Ah).
Step 2:
Set (Mode of operation: 6060h) to Cyclic synchronous position mode (csp
mode) value = 0x08, and check (Mode of operations Display: 6061h) = 0x08.
Step 3:
Change (Controlword: 6040h) from the value 0x06
→
0x07
→
0x0F to
make the control system Servo On state, and the drive starts to move according
to (Target position: 607Ah).