Icop IM242S Series Скачать руководство пользователя страница 8

IM242S       

                                                                                                                               

     

User Manual

 

2.9 Pin Assignment 

ICOP IM242S uses a standard SATA pin-out. See Table 9 for IM242S pin assignment. 

Table 9: ICOP IM242S Pin Assignment 

Signal Name 

Pin #  Pin # 

Signal Name 

 

 

75 

GND 

3.3V 

74 

73 

GND 

3.3V 

72 

71 

GND 

3.3V 

70 

69 

GND 

NC 

68 

67 

NC 

Notch 

66 

65 

Notch 

Notch 

64 

63 

Notch 

Notch 

62 

61 

Notch 

Notch 

60 

59 

Notch 

NC 

58 

 

 

NC 

56 

57 

GND 

NC 

54 

55 

NC 

NC 

52 

53 

NC 

NC 

50 

51 

GND 

NC 

48 

49 

RX+ 

NC 

46 

47 

RX- 

NC 

44 

45 

GND 

NC 

42 

43 

TX- 

NC 

40 

41 

TX+ 

DEVSLP 

38 

39 

GND 

NC 

36 

37 

NC 

NC 

34 

35 

NC 

NC 

32 

33 

GND 

NC 

30 

31 

NC 

NC 

28 

29 

NC 

NC 

26 

27 

GND 

NC 

24 

25 

NC 

NC 

22 

23 

NC 

NC 

20 

21 

GND 

Notch 

18 

19 

Notch 

Notch 

16 

17 

Notch 

Notch 

14 

15 

Notch 

Notch 

12 

13 

Notch 

DAS/DSS 

10 

11 

NC 

Содержание IM242S Series

Страница 1: ...User Manual M 2 2242 SSD IM242S Series Version 1 0...

Страница 2: ...Humidity 6 2 4 3 Shock and Vibration 6 2 4 4 Mean Time between Failures MTBF 6 2 5 CE AND FCC COMPATIBILITY 7 2 6 ROHS COMPLIANCE 7 2 7 RELIABILITY 7 2 8 TRANSFER MODE 7 2 9 PIN ASSIGNMENT 8 2 12 SEE...

Страница 3: ...IM242S User Manual 3 REVISION HISTORY Revision Description Date Rev 1 0 Version 1 0 Released Jan 2019...

Страница 4: ...including TRIM NCQ and S M A R T In addition the exclusive industrial oriented firmware provides a flexible customization service making it perfect for a variety of industrial applications 1 2 Produc...

Страница 5: ...8GB 16GB 32GB 64GB 128GB 256GB 1CH 2CH Sequential Read max 140 MB s 200 MB s 270 MB s 450MB s 530 MB s 530 MB s 530 MB s Sequential Write max 25 MB s 25 MB s 60 MB s 50 MB s 100 MB s 120 MB s 210 MB s...

Страница 6: ...anical Shock Duration 0 5ms 1500 G 3 axes IEC 68 2 27 2 4 4 Mean Time between Failures MTBF Table 7 summarizes the MTBF prediction results for various IM242S configurations The analysis was performed...

Страница 7: ...TBW Total Bytes Written Unit TB Capacity Sequential workload Client workload 08GB 23 4 15 6 16GB 46 8 31 2 32GB 93 6 62 4 64GB 187 2 124 8 128GB 374 4 208 3 256GB 748 8 416 6 Note 1 Sequential Mainly...

Страница 8: ...70 69 GND NC 68 67 NC Notch 66 65 Notch Notch 64 63 Notch Notch 62 61 Notch Notch 60 59 Notch NC 58 NC 56 57 GND NC 54 55 NC NC 52 53 NC NC 50 51 GND NC 48 49 RX NC 46 47 RX NC 44 45 GND NC 42 43 TX N...

Страница 9: ...IM242S User Manual 9 NC 8 9 NC NC 6 7 NC 3 3V 4 5 NC 3 3V 2 3 GND 1 GND 2 10 Mechanical Dimensions Figure 2 ICOP IM242S diagram TSOP...

Страница 10: ...tion User has to avoid hot plugging the SSD which is configured as boot device and installed operation system Surprise hot plug The insertion of a SATA device into a backplane combine signal and power...

Страница 11: ...e flash device s occurs through the flash interface 3 2 SATA III Controller ICOP IM242S is designed with 88NV1120 a SATA III 6 0Gbps Gen 3 controller The Serial ATA physical link and transport layers...

Страница 12: ...e Bad Blocks is detected it will be flagged and not be used anymore The SSD implement Bad Blocks management Bad Blocks replacement Error Correct Code to avoid data error occurred The functions will be...

Страница 13: ...ay be either directly connected to a host or connected to a host through a cable For connection via cable the cable should be no longer than 1meter The SATA interface has a separate connector for the...

Отзывы: