iCool Lite 

2014 Model 

 

OWNER’S MANUAL

New Features for 2014:

Lighter weight:  

5Kg (10 lbs) lighter than the previous model

Smaller Size:    

Height reduced by 52mm (2 inches)

All New Water  
Circulation System:  

A new light weight ultra compact hi power water pump small enough to operate externally  

 

 

 

for easy cleaning and maintainance.

 

 

 

The new pump has a fully automatic self priming function that will automaticall try to clear  

 

 

 

trapped air. If it can not do so after several attempts it will shut down and warn the user. 

 

 

 

With optional low cost attachments, the new pwater pump system allows you to use your Lite  

 

 

 

with virtually any small pool, spa or bath tub.

   

The new pump system operates from very safe low voltage for total safety.

 

 

         

WARNING: 

Do not use this machine with Chlorine, Bromide or Salt!

 

         These chemicals are very corrosive and can damage the stainless steel heat exchanger tank.

 

         Bacteria grows much more slowly in very cold water so there is no need to use such harsh chemicals. 

                     Half a small cup of a standard bathroom disinfectant or mouth wash will safely control bacteria. 

OWNER’S MANUAL FOR iCOOL RECOVERY SYSTEMS

 

Содержание iCool Lite

Страница 1: ...several attempts it will shut down and warn the user With optional low cost attachments the new pwater pump system allows you to use your Lite with virtually any small pool spa or bath tub The new pump system operates from very safe low voltage for total safety WARNING Do not use this machine with Chlorine Bromide or Salt These chemicals are very corrosive and can damage the stainless steel heat e...

Страница 2: ...old can be quickly lost Good insulation reduces these losses Good insulation will result in much faster cooling and save a lot of electricity HOLDING THE SET TEMPERATURE In normal conditions once your pool reaches your set temperature your iCool Lite has been designed to have enough cooling power to continue to hold that temperature even if several athletes are using the pool NEVER USE CORROSIVE C...

Страница 3: ...TRAPPED AIR IN THE SYSTEM OR THE HOSES As you gain experience using an ice bath system you will learn to overcome this quickly and easily ABOUT PUMPS Water flow through your iCool Lite is produced by a high quality long life circulating type pump that is fitted into the lower pool connecting hose For total safety it operates at 12 volts DC and is completely water proof Circulating type pumps are n...

Страница 4: ...l STEP 1 Before you fill the pool you must connect the PUMP MODULE and the 2 hoses provided to the inlet and outlet fittings on the Lite unit ICool hoses have convenient snap fittings that are very quick and easy to use The large hose with the circulating pump in line connects from the bottom of the pool to the bottom inlet fitting on the Lite SCREW THE BIGGER OF THE 2 CONNECTION HOSES PROVIDED TO...

Страница 5: ...s takes it very close to the temperature that water freezes solid Following international safety standards your iCool will not accept water temperature settings below 6ºC or 42ºF as this would put athletes using the system unattended at risk of hypothermia However the iCool is easily powerful enough to freeze the water inside the system itself and if this happens the safety screen above will appea...

Страница 6: ...E iCOOL LOGO WILL FLASH WHITE The iCool Logo is the system STATUS BAR it changes colour or flashes to give a clear indication of each function While the software is loading it will flash white the welcome screen shown above will appear and then a black screen appears for about 15 seconds while the computers test the safety systems When your personal logo screen see examples below appears it will s...

Страница 7: ... water does not flow smoothly within a minute please check that the hose from the bottom of the pool is flat on the floor and no part of it is higher than the top of the water Check that the water in the pool is higher than the pump If this does not correct the problem the system will sound an alarm and a red warning screen will appear with information about how to correct the water flow problem S...

Страница 8: ...e reading exceeds this you need to move the system to a cooler area or improve the air flow The PRESET TEMPERATURE WINDOW always shows your selected temperature This is the temperature the water will be automatically cooled or heated to and maintained at CHANGING THE TEMPERATURE SETTING You can change your preset temperature at any time by touching the CHANGE SETTING BUTTON this will take you to t...

Страница 9: ...so there usually no need to use this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the sound level from the screen MAIN COOLING FAN SPEED This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to con...

Страница 10: ...ed athlete using the pool your system will not allow you to set temperatures below 5 C 40 F If the model you are using is the contrast model which also provides heating for contrast therapy you cannot set the temperature above 45 C 112 F because of the risk of scalding These temperature limits have been set after wide consultation with the sporting industry around the world There are no demonstrat...

Страница 11: ... does perfectly The session timer is set up from the main TIME SETTING SCREEN by touching the SET COUNTDOWN button The numbers on the setting screen in the bottom right hand corner will begin to flash and you can use the left right and up down arrows to change the time in minutes and seconds Once you have set the time you want your athletes to remain in the bath touching the DISPLAY COUNTDOWN FULL...

Страница 12: ...elp system Detailed and well illustrated helpful information on every important subject to do with the operation of your iCool is available from almost any screen simply by touching the help button Touching any help button will take you to the screen illustrated on the right The screen has eight menu buttons covering all of the important topics you are ever likely to need assistance with When you ...

Страница 13: ... run screen for more than 10 seconds you can only lock from this main screen A picture of a lock will appear While ever this lock is visible it is not possible to make any inputs or to change screens To unlock the system and returned to normal repeat the procedure Touch and hold the iCool icon for more than 10 seconds The lock will disappear and all functions will return to normal You can flip for...

Страница 14: ...p it sometimes occurs that the water flow monitoring system may be too sensitive and will stop the pump because it appears that water is not flowing properly We allow this to be over ridden if it becomes troublesome Instructions on how to do this will appear on the screen automatically if this happens It must be remembered of course that if you disarm this system the pump is no longer protected fr...

Страница 15: ...0 Litres Per Min 30 Litres Per Min 30 Litres Per Min LOCKING MAIN POWER PLUG 3 Pin Heavy Duty 3 Pin Heavy Duty 3 Pin Heavy Duty WEIGHT KG POUNDS 21KG 49 Lbs 38KG 84 Lbs 40KG 88 Lbs DIMENSIONS H W D in mm 240x420x300 545x475x290 545x475x290 DIMENSIONS H W D Inches 10x16 5x11 8 21 5x18 7x11 4 21 5x18 7x11 4 IF THE STATUS BAR LIGHT ON TOP OF THE ICOOL TURNS RED WHEN YOU START THE COOLING CYCLE If the...

Страница 16: ...ivered in your country due to local conditions or regulations or other factors Also certain specifications may change due to ongoing research and development because we are constantly improving our products We welcome your feedback and suggestions and we offer support for general enquiries and information for specific countries on our website at Thank you for choosing iCool the world s most popula...