Safety Information
■
De-pressurize and vent system prior to installation or removal
■
Confirm chemical compatibility before use
■
DO NOT
exceed maximum temperature or pressure specifications
■
ALWAYS
wear safety goggles or face-shield during installation and/or service
■
DO NOT
alter product construction
Warning | Caution | Danger
Indicates a potential hazard. Failure to follow all warnings
may lead to equipment damage, personal injury, or death.
Note | Technical Notes
Highlights additional information or detailed procedure.
Hand Tighten Only
Over tightening may permanently damage product.
Do Not Use Tools
Use of tool(s) may damage product beyond repair
and potentially void product warranty.
Personal Protective Equipment (PPE)
Always utilize the most appropriate PPE during
installation and service of Truflo products.
Pressurized System Warning
Sensor may be under pressure. Take caution to vent
system prior to installation or removal. Failure to do so
may result in equipment damage and/or serious injury.
WARNING
General Information
Function/Description
Specification
Operating Voltage
10 – 30VDC
Current Compensation
60mA max.
Control Communication
RS-485 Modbus
Transmitter
4-20mA
Relay Output
10A 30VDC
|
NO
|
NC
Flow Rate GPM | LPM
0.0 – 999.9
Fluid
H2O
|
Liquid Chemical Media
Accuracy
± 0.5% of F.S. @25ºC
Response Frequency
5K Hz
Max Flow Rate
10m/s
|
33ft/s
Min Flow Rate
0.1m/s
|
0.3ft/s
Materials of Construction
Rotor: ETFE Tefzel
®
|
Rotor Pin: Zirconium Ceramic
|
Rotor Bushings: Ceramic
Sensor Body: PVC/PP/PVDF/316SS
O-ring material
FPM
|
EPDM
*
|
FFKM
*
Operating Temperature
PVC < 60ºC
|
PP < 80ºC
|
PF < 100ºC
Protection Rating
NEMA 4X
|
IP66
|
General Purpose
Approval
CE
|
RoHS
*
Optional
TIF Series
Multi-Function Batching Paddle Wheel Flow Meter
2