2141 ICON Way, Vacaville, CA 95688
‐
Tel: 707.564.4000
– www.iconaircraft.com
SERVICE BULLETIN
SB-110521 REV A
ICA009719-D
PAGE
7
of
8
Figure 5: Fuel Pump Extension Connectors Location
28.
Disconnect Sig Fuel Pump 1 connector from fuselage wire harness connector D9086J. If necessary,
remove zip tie holding connectors to fuselage wire harness.
29.
Visually inspect both connectors and ensure that contacts are fully inserted in each connector.
Gently slide each wire back and forth to ensure that the contact is locked in position.
30.
Reconnect Sig Fuel Pump 1 and D9086J connectors. Ensure secondary locking mechanism is fully
engaged in each connector.
31.
Disconnect Sig Fuel Pump 2 connector from fuselage wire harness connector D9099J.
32.
Visually inspect both connectors and ensure that contacts are fully inserted in each connector.
Gently slide each wire back and forth to ensure that the contact is locked in position.
33.
Reconnect Sig Fuel Pump 2 and D9099J connectors. Ensure secondary locking mechanism is fully
engaged in each connector.