SERVICE BULLETIN
SB-110521 REV A
ICA009719-D
PAGE
3
of
8
have either a blue seal or an orange seal in this location. The replacement connector must have the
orange seal installed.
13.
Slide the new connector contact secondary lock (ICA011057) onto the wires.
14.
Insert the contacts into a new connector (ICA011058) with the same location and orientation that the
wires were in when removed from the old connector.
The contact on the black wire inserts into the “B”
side of t
he connector and the contact on the red wire inserts into the “A” side. See
. Ensure
that the contacts positively seat into the connector body. A “click” is heard when the contact seats and
a gentle tug on the wire confirms.
Figure 1: Connector wire locations
15.
Seat the secondary lock onto the back of the connector to ensure contact retention.
16.
Inspect the pin terminals inside both fuel pump connectors. Gently align if necessary. See
Flat
s
B terminal
–
black
wire
A terminal
–
Red wire
Orange seal (ICA013937)
Connector (ICA011058)