TRANSCEIvER CoNTRoLLER
6-17
Transceiver Registration screen
■
Transceiver Settings
Register the IP100H or IP100FS settings.
L
After the registration is completed, you must reboot the IP100H.
Transceiver Controller > Transceiver Settings > Transceiver Registration
1
2
3
4
5
6
7
8
9
10
1
TRX No. ��������
Selects the number that the IP100H or IP100FS is registered to.
(Default: 1)
L
Up to 50 terminals can be registered.
2
Transceiver Model ����
Select either the IP100H or IP100FS.
(Default: IP100H)
3
Name ����������
Enter a transceiver name of up to 31 characters.
4
Unit ID ���������
Enter the 4 digit individual number between 0001 and 9999.
(Default: 0001)
5
Password ��������
Enter a password to access to the RoIP Gateway.
(Default: iptrx)
L
Up to 12 characters, lower or upper letters, numbers, and symbols can be
used.
6
Transceiver Port Number
Enter the port number (UDP port) that the IP100H will use to
communicate with the RoIP Gateway.
Information
L
•
The set port number (RTP) and the port 1 (RTCP) are used for
communication.
•
We basically recommend that you use the default port number.
•
The default number differs, depending on [TRX No.], as shown below.
Default: TRX No. 1 (30000), TRX No. 2 (30002), TRX No. 3 (30004),
TRX No. 4 (30006), .............................., TRX No. 50 (30098)
•
Setting range: Even numbers between 2 and 59998.
Some numbers may not be usable.
•
Do not set the port number that has already been used by another connection
setting.
•
When [Transceiver Model] (
2
) is set to “IP100FS,” the port number is not
displayed.