6-1
SECTION 6
ADJUSTMENT PROCEDURE
STANDARD SIGNAL
GENERATOR
RF POWER METER
Supplied DC power cable
25 A fuses
T
o
[RX ANT]
T
o [USB]
To [DC13.8V]
T
o [SER
VICE]
[GND]
(3.5 mm, ⅛ in (d))
PLUG INFORMATION
Parts name:
AP-338
Order number: 5610000420
[MIC]
T
o
[TX
ANT]
Always connect the power
meter during adjustment.
To [REF IN 10 MHz]
<Rear view>
Supplied USB cable
PC
_
+
DC POWER SUPPLY
10 MHz
REFERENCE FREQUENCY
SIGNAL SOURCE
+
−
AC MILLIVOLTMETER
AUDIO GENERATOR
+
−
+
4.7 µF
6-1 PREPARATION
■
REQUIRED EQUIPMENT
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
Adjustment software ID-RP3 ADJ
Programming cable USB cable ( Supplied with the repeater)
DC power supply
Output voltage:
13.8 V
Current capacity: 10 A or more
Standard signal
generator (SSG)
Frequency range: 0.1 ~ 300 MHz
Output level:
−20 to 90 dBμV
(−127 to −17 dBm)
RF power meter
(50 Ω terminated)
Measuring range: 0.1 ~ 30 W
Frequency range: 100 ~ 300 MHz
SWR:
1.2 : 1 or less
10 MHz reference
frequency signal
source
Frequency:
10.000000 MHz
Accuracy: ±5×10
-4
ppm or less
Output level:
97 dBμV (−10 dBm)
Audio generator (AG)
Frequency range: 300 ~ 3000 Hz
Output level:
1 ~ 500 mV
AC millivoltmeter
Measuring range: 1 mV ~ 10 V
■
SAVE THE PROGRAMMING DATA
• Adjusting the repeater will change the programming setting.
• Before adjusting, save the programming data of the repeater with the programming software.
After adjusting, write back the programming data.
■
CONNECTIONS