![Icom IC-V80 Скачать руководство пользователя страница 48](http://html2.mh-extra.com/html/icom/ic-v80/ic-v80_instruction-manual_3761314048.webp)
42
10
SET MODES
■
Initial Set mode items
D
Key-touch beep
Turn the confi rmation beeps ON (default) or OFF.
• When changing the beep level, beeps sound at the level.
(default: bEP. 2)
D
Time-out timer
To prevent accidental prolonged transmission, the
transceiver has a time-out timer. The function inhibits
continuous transmissions longer than the set time pe-
riod (1–30 minutes). (default: tot. 5)
• tot.OF :
Turns OFF the function.
• tot. 1–30 : The transmission is cut OFF after the set time
period ends.
Approximately 10 seconds before the time-out timer
is activated, the transceiver emits a beep tone as a
warning.
Be careful!
When using the BP-263 battery case,
the batteries will become hot if this Time-out Timer
function is turned OFF or set to a long time period,
and transmission is made for long periods.
D
Auto Repeater
The Auto Repeater function automatically turns the du-
plex setting and tone encoder ON or OFF when the op-
erating frequency falls within or outside of the general re-
peater output frequency range (145.200–145.495 MHz,
146.610–146.995 MHz and 147.000–147.395 MHz).
The frequency offset and repeater tone frequency are
not changed by the Auto Repeater function; reset these
frequencies, if necessary.
• RPt.OF : Turns OFF the function.
• RPt.R1 : Activates only duplex. (default)
• RPt.R2 : Activates duplex and tone.
D
Auto power-OFF
The transceiver can be automatically turned OFF, when no
key operation is performed for the specifi ed time period.
30 minutes, 1 hour, 2 hours and OFF are selectable.
• POF.OF :
Turns the function OFF. (default)
• POF.30/1H/2H :
The transceiver is automatically turned
OFF, when no key operation is performed
for the specifi ed time period.
NOTE:
The time period is retained, even if the trans-
ceiver is turned OFF by the Auto Power OFF func-
tion. To cancel the function, select “POF.OF.”
D
Lockout
Set the transmission lockout (temporary transmission
inhibit) capability.
• RLO.OF :
Turns OFF the function. (default)
• RLO.RP :
The transmit is inhibited when a signal
with an unmatched subaudible tone is re-
ceived.
• RLO.bU :
Transmit is inhibited when a signal is re-
ceived.
D
Squelch delay
Set the squelch delay to short or long. The delay prevents the
squelch from repeatedly opening and closing, while receiving
the same signal.
• Sqd. S : Short squelch delay. (default)
• Sqd. L : Long squelch delay.
D
DTMF speed
Set the rate at which DTMF memories send individu-
al DTMF characters to accommodate your operating
needs.
• dtd. 1 : 100 milliseconds interval; 5.0 cps rate (default)
• dtd. 2 : 200 milliseconds interval; 2.5 cps rate
• dtd. 3 : 300 milliseconds interval; 1.6 cps rate
• dtd. 5 : 500 milliseconds interval; 1.0 cps rate
(cps=characters per second)
Only USA version of IC-V80