6
OTHER FUNCTIONS
6-12
Resetting
If the transceiver has a malfunction caused by an external factor such as static electricity, reset it using the Partial
Reset or All Reset function.
BE CAREFUL!
An All Reset clears all programming and returns all settings to the factory defaults.
D
Partial Reset
1. Rotate [VOL] counter-clockwise to turn OFF the
transceiver.
2.
While holding down [H/M/L], rotate [VOL]
clockwise to turn ON the transceiver.
•
“Icom” and the voltage are displayed, and then the
operating frequency is displayed.
TIP:
A Partial Reset resets the operating settings to
their defaults without clearing the following:
• Memory Channel contents
• Scan Edge contents
• Call Channel contents
• DTMF memory contents
• Home Channel settings
D
All Reset
1. Rotate [VOL] counter-clockwise to turn OFF the
transceiver.
2.
While holding down [SET], [BAND], and [H/M/L],
rotate [VOL] clockwise to turn ON the transceiver.
•
“CLEAR,” “Icom,” and the voltage are displayed, and
then the operating frequency is displayed.