4 - 2
4-2 PLL ADJUSTMENT
REFERENCE
FREQUENCY
VCO
VOLTAGE
1ST LO
VOLTAGE
3RD LO
VOLTAGE
3RD LO
FREQUENCY
BFO
VOLTAGE
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
1
2
1
2
3
4
1
1
1
1
2
• Displayed frequency
: 29.99999 MHz
• Mode
: USB
• Displayed frequency
: 29.99999 MHz
• Mode
: USB
• Displayed frequency
: 0.03000 MHz
• Mode
: USB
• Displayed frequency
: 60.00000 MHz
• Mode
: USB
• Displayed frequency
: 30.00000 MHz
• Mode:
USB
• Displayed frequency
: 30–60.00000 MHz
• Mode
: USB
• Displayed frequency
: 30–60.00000 MHz
• Mode
: USB
• Displayed frequency
: 9.4615 MHz
• Mode
: FM
• Displayed frequency
: 14.100000 MHz
• Mode
: USB
• Displayed frequency
: 14.100000 MHz
• Mode
: AM
PLL
PLL
PLL
PLL
PLL
PLL
Connect the fre-
quency counter to
P1.
Connect the RF
voltmater to P1.
Connect the DC
voltmeter to HCP71.
Connect the RF
voltmeter to P91.
Connect the RF
voltmeter to P91.
Connect the fre-
quency counter to
P151.
Connect the RF
voltmeter to P201.
60.00000 MHz
Maximum voltage
4.0 V
More than 0.8 V
4.0 V
More than 0.8 V
More than 0.18 V
More than 0.022 V
9.4614–9.4616 MHz
More than 0.022 V
Less than 280 µV
PLL
PLL
PLL
L2
L4, L5
C86
Verify
C76
Verify
Verify
Verify
Verify
Verity
*This output level of the standard signal generator (SSG) is indicated as SSG’s open circuit.