CS-F620TR Programming Software Manual
(rev 1.0) -
DTMF Encode Programming Screen
48
Group
Field
Description
Default
Suggested
Settings
Timer
First Digit
Enter from 0 to 32.767 (in seconds). Sets
period of time in which the first digit of the
DTMF sequence will sound. Useful to provide
extra “wakeup” time for various DTMF decode
systems.
.1
Set as
needed.
Timer
Special
Digit
Enter from 0 to 32.767 (in seconds). Sets
period of time in which special digits “*” (same
as “E”) and “#” (same as “F”) will sound.
These tones are often used as control codes and
it is sometimes useful to have special control
over their tone duration.
.1
Set as
needed.
Timer
Digit time
Enter from 0 to 32.767 (in seconds). Sets
period of time in which the each digit of the
DTMF sequence will sound (other than Special
Digit or First Digit).
.1
Set as
needed.
Timer
Inter Digit
Enter from 0 to .255 (in seconds). Sets period
of time between the sounding of each DTMF
digit.
.1
Set as
needed.
When done editing in this programming screen you can proceed to other programming
screens, save your programming parameters to a file or proceed to writing the
information to the radio (assuming that editing has been finished for all other required
programming screens also).