CS-F620TR Programming Software Manual
(rev 1.0) -
PassPort Programming Screen
24
Group
Field
Description
Default
Suggested
Settings
RSSI
Condition
Preferred
Enter from 0 to 255. If the number set here is
below the Min field, the Min field will be
adjusted to equal this. As a radio is looking for
a site to register to, it must see an RSSI of this
value or more before it attempts registration.
To cross-reference this RSSI value to applied
signal strength, please refer to the chart on page
71.
0
Set as
needed. A
good value to
work with is
21. Setting
this value
somewhat
higher than
the Min field
will help
prevent the
radio from
repeatedly
registering to,
and then
loosing, a
marginal site
(particularly
the one it just
left).
RSSI
Condition
Look Back
Enter from 0 to 255. The Look Back field must
be enabled for this field to matter. As the radio
“looks back” at its home site, it must see an
RSSI of this value or more before it attempts
registration.
0
Set as
needed. A
good value to
work with is
35. Setting
this value
even higher
than
“Preferred”
will ensure
that the
“Look Back”
function will
work with
less
frustration for
the user.
RSSI
Condition
Los Time
Enter from 0 to 255 (seconds). This is a timer
that starts as soon as received signal value has
gone below the “RSSI Minimum”. If the radio
does not see a signal at or above the “RSSI
Minimum” before the time on this timer
expires, the radio will initiate searching for
another site.
0
Set as
needed. A
good value to
work with is
20 seconds.
RSSI
Condition
Averaging
Select “Enable” or “Disable”. Sets the radio to
average the received RSSI signal over 2
samples to provide more reliable signal
strength readings.
Disable
(Blank)
Set as
needed.
Generally
should be
enabled.