36
9
TROUBLESHOOTING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center.
PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
No power comes on.
• The battery is exhausted.
• Recharge the battery pack.
pp. 29–31
• Bad connection for the battery pack.
• Reattach the battery to the transceiver.
p. 7
No sound comes from the
• The Squelch level is too deep.
• Set the squelch to the threshold point.
p. 9
speaker.
• The Volume level is too low.
• Set
[VOL]
to a suitable level.
Transmitting impossible.
• A WX channel or the NAVI band is selected.
• Set to COM band in frequency mode.
p. 8
• The battery is exhausted.
• Recharge the battery pack.
pp. 29–31
The operating frequency or • The lock function is activated.
• Hold down
[
]
for 2 seconds to turn the Lock p. 9
memory channel can not
function OFF.
be changed.
Scan does not start.
• All memory channels in the selected bank are • Set the “TAG” settings of desired channels.
p. 20
not programmed as “TAG” channels.
• The Squelch is open.
• Set the squelch level tighter.
p. 9
• There is not more than 2 memorized channels • Program 2 or more memory channels.
pp. 13, 14
No beep sounds.
• Beep tones are turned OFF.
• Turn ON the beep tone.
➥
IC-A14: Push
[FUNC]
, then push
[BEEP](8)
. p. 22
➥
IC-A14S: Turn the beep tone ON in set mode. pp. 22, 25
D
CP-22 fuse replacement
If the fuse blows, or the receiver stops functioning while using
the optional CP-22
cigarette
lighter
cable
, find the source
of the problem and repair it. Replace any blown fuse with a
new rated one (FGB 8 A) as shown to the right.
Fuse 8 A