15-20
15
SET MODE
Default Gateway (Valid after Reboot)
(Default:
. . .
)
When you remotely control the IC-7850 using the op-
tional RS-BA1, a default gateway setting is required.
Push [
t
u
](F) to select the item, and then turn
[MAIN DIAL] to set the address.
This setting is valid when "OFF" is selected in the
[DHCP (Valid after Reboot)] item.
This setting takes effect after reboot.
Primary DNS
Server (Valid after Reboot)
(Default:
. . .
)
If there are two DNS server addresses, enter the pri-
mary DNS server address.
Push [
t
u
](F) to select the item, and then turn
[MAIN DIAL] to set the address.
This setting is valid when "OFF" is selected the
[DHCP (Valid after Reboot)] item.
This setting takes effect after reboot.
2nd DNS
Server (Valid after Reboot)
(Default:
. . .
)
If there are two DNS server addresses, enter the sec-
ondary DNS server address.
Push [
t
u
](F) to select the item, and then turn
[MAIN DIAL] to set the address.
This setting is valid when "OFF" is selected the
[DHCP (Valid after Reboot)] item.
This setting takes effect after reboot.
■
Others set screen (continued)
Network Name
When you remotely control the IC-7850 using the op-
tional RS-BA1, enter a network name of up to 15 char-
acters.
Usable characters:
Characters (a–z, A–Z, 0–9) and symbols (! # $ %& " `
^ + – . , ; = ( ) [ ] { } _ ~ @)
• Push [EDIT](F) to enter the edit mode.
• Push [ABC] or [abc] to toggle the character type be
-
tween upper case and lower case letters.
• Push [123] or [Symbol] to toggle the character type
between numbers and symbols.
• Rotate [MAIN DIAL] to select a character.
• Push [
t
](F) to move the cursor to the left, push [
u
]
(F) to move the cursor right.
• Push [DEL](F) to delete the selected character.
• Push [EXIT/SET] to cancel and exit the edit mode.
• Push [SET](F) to save.
Network Control (Valid after Reboot)
(Default: OFF)
When you remotely control the IC-7850 using the op-
tional RS-BA1, select "ON."
• OFF: Turn OFF the function.
• ON: Turn ON the function.
Control Port (UDP) (Valid after Reboot)
(Default: 50001)
When you remotely control the IC-7850 using the
optional RS-BA1 software, set a port number for the
control signal transfers between the IC-7850 and the
remote station.
• Set the same port number to the remote station.
• This setting takes effect after reboot.
Serial Port (UDP) (Valid after Reboot)
(Default: 50002)
When you remotely control the IC-7850 using the op-
tional RS-BA1 software, set a port number for the seri-
al data transfers between the IC-7850 and the remote
station.
• Set the same port number to the remote station.