
■
Programmed scan operation
q
Push
[EXIT/SET] several times to close any multi-
function screens, if necessary.
w
Select the VFO mode.
e
Select the desired operating mode.
• The operating mode can also be changed while
scanning.
r
Push
[SCAN] (F-5) to select the scan screen.
t
Set
[RF/SQL] open or closed.
• See page 113 for squelch condition.
• If the
[RF/SQL] control function is set as “AUTO,” the
squelch is always open in the SSB, CW, RTTY and
PSK modes. (pp. 2, 37, 136)
y
Push
[PROG] (F-1) to start the programmed scan.
• “
” and decimal points blink while
scanning.
u
When the scan detects a signal, scan stops,
pauses or ignores it depending on the resume
setting and the squelch status.
i
To cancel the scan, push
[PROG] (F-1).
• Rotating the main dial also cancels the scan.
o
Hold down
[RECALL] (F-5) for 1 second to recall
the frequency that is set before starting the scan, if
desired.
If the same frequencies are programmed into the
scan edge memory channel P1 and P2,
programmed scan will not start.
■
∂
F scan operation
q
Push
[EXIT/SET] several times to close any multi-
function screens, if necessary.
w
Select VFO mode or a memory channel.
e
Select the desired operating mode.
• The operating mode can also be changed while
scanning.
r
Push
[SCAN] (F-5) to select the scan screen.
t
Set
[RF/SQL] open or closed.
• See page 113 for squelch condition.
• If the
[RF/SQL] control function is set as “AUTO,” the
squelch is always open in the SSB, CW, RTTY and
PSK modes. (pp. 2, 37, 136)
y
Set the
∂
F span by pushing
[
∂
F SPAN] (F-4).
• ±5 kHz, ±10 kHz, ±20 kHz, ±50 kHz, ±100 kHz,
±500 kHz and ±1000 kHz are selectable.
u
Rotate the main dial to set a center frequency of
the
∂
F span.
i
Push
[
∂
F] (F-2) to start the
∂
F scan.
• “
” and decimal points blink while scanning.
o
When the scan detects a signal, the scan stops,
pauses or ignores it depending on the resume
setting and the squelch status.
!0
To cancel the scan, push
[
∂
F] (F-2).
• Rotating the main dial also cancels the scan.
!1
Hold down
[RECALL] (F-5) for 1 second to recall
the frequency that was set before starting the scan.
115
7
SCANS
F-1
F-5
EXIT/SET
Main dial
[RF/SQL]
PROG
SCAN
RECALL
F-2
F-4
∂
F SPAN
∂
F
F-5
EXIT/SET
[RF/SQL]
SCAN
RECALL
/
Содержание IC-7600
Страница 1: ...INSTRUCTION MANUAL HF 50 MHz TRANSCEIVER i7600 ...
Страница 192: ...MEMO ...
Страница 193: ...MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ...
Страница 194: ...MEMO ...
Страница 195: ...MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ...