INSTALLATION AND CONNECTIONS
2-4
Connecting an external DC power supply
Confirm that the transceiver is OFF before connecting
the DC power cable.
L
We recommend using Icom’s optional PS-126
(DC 13.8 V/25 A) power supply.
L
When connecting a non-Icom DC power cable, the
transceiver needs:
•DC 13.8 V (Capacity: At least 21 Amps)
• A power supply with an over current protective line and
low voltage fluctuation or ripple.
_
+
Connecting the antenna tuner
The AH-4 matches the IC-7300 to
the optional
AH-2b or a long wire antenna more than 7 m/23 ft long
(between 3.5 MHz and 50 MHz).
NOTE
: Before connecting, be sure to turn OFF the
transceiver power.
L
See the AH-4 instruction manual for installation and
connection details.
GND
AH-4
GND
[ANT]
IC-7300
[TUNER]
HF band long wire
antenna
Or to an optional AH-2b
Control cable
PS-126
Non-Icom DC power supply
PS-126
AC cable
DC power cable
IC-7300
q
w
When disconnecting, firmly
push down the locking tab
and then pull the connector
out of the socket.
GND
Supplied DC
power cable
Black
Red
Fuses
CAUTION: DO NOT
touch the cooling fan on the rear panel
of the transceiver after transmitting continuously for long
periods of time. The transceiver becomes extremely hot.
For European versions
Connect to
power supply
DC 13.8 V/21 A
or more
Previous view