2
INSTALLATION AND CONNECTIONS
2-6
Linear amplifier connections
D
Connecting the IC-PW1/IC-PW1EURO
See the illustration below to connect the optional IC-PW1 or IC-PW1EURO
hf/50
mhz
all
band
1
kw
linear
amplifier
.
Refer to the amplifier’s instruction manual for operation.
EXCITER
1
1&2
[ACC-1]
[REMOTE]
[ANT]
[ANT]
IC-7300
GND
GND
[ACC]
[REMOTE]
[INPUT 1]
IC-PW1/IC-PW1EURO
To an
antenna
Remote control cable
ACC cable
7-pin side
OPC-599 conversion cable
AC outlet
Coaxial cable
Non-European versions: 100~120/200~240 V
European version:
230 V
D
Connecting a non-Icom linear amplifier
See the illustration below to connect a non-Icom linear amplifier.
L
We recommend that you use a linear amplifier with a specified input power of 100 watts or more. If you use an
amplifier with a specified drive level of less than 100 watts, adjust the IC-7300’s output power to the specified
level before transmitting. Otherwise the linear amplifier may be damaged.
RF OUT
RF IN
ALC
SEND
[ALC]
[SEND]
[ANT]
GND
IC-7300
To an antenna
Non-Icom linear amplifier
R
WARNING!
•
The maximum signal level of the [SEND] jack is 16 V/0.5 A DC. Use an external unit if your non-Icom linear amplifier requires
a control voltage and/or current greater than specified.
• The ALC input level must be in the range 0 to –4 V. The transceiver does not accept a positive voltage. Non-matched ALC
and RF power settings could overheat or damage the linear amplifier.
•
When using a linear amplifier such as the IC-PW1 or IC-PW1EURO, set the RF POWER in the Multi-function menu to keep
the ALC meter in the red zone.
L
See page 3-10 for details on the RF POWER
L
See page 3-11 for details on the ALC zone.