190
18
CONTROL COMMAND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Cmd.
Sub cmd.
Data
Description
20
02
00
00*
2
Send/read Auto DV RX status output OFF
01*
2
Send/read Auto DV RX status output ON
01
see p. 194 Output DV RX status
02
see p. 194 Read DV RX status
*
1
The counter can be inserted into only one channel.
*
2
Output setting is automatically turned OFF after turning
the power OFF, then ON.
• Character code setting
Command : 1A 00, 1A 05 0169, 1A 05 0173,
1A 05 0175, 1A 05 0176, 1A 05 0177,
1F 02, 20 0001, 20 0002, 20 0101,
20 0102
Character
ASCII code
Character
ASCII code
A–Z
41–5A
a–z
61–7A
0–9
30–39
Space
20
!
21
#
23
$
24
%
25
&
26
\
5C
?
3F
"
22
’
27
`
60
^
5E
+
2B
–
2D
✱
2A
⁄
2F
.
2E
,
2C
:
3A
;
3B
=
3D
<
3C
>
3E
(
28
)
29
[
5B
]
5D
{
7B
}
7D
¦
7C
_
5F
¯
7E
@
40
• Operating frequency
Command : 00, 03, 05
q
X
X
X
X
X
w
e
X
r
t
X
X
X
X
10 Hz digit:
0–9
1 Hz digit:
0–9
1 kHz digit:
0–9
100 Hz digit:
0–9
100 kHz digit:
0–9
10 kHz digit:
0–9
10 MHz digit:
0–9
1 MHz digit:
0–9
1000 MHz digit:
0–1
100 MHz digit:
0–4
• Operating mode
Command : 01, 04, 06
q
X
X
X
X
w
q
Operating mode
w
Filter setting
00: LSB
03: CW
07: CW-R
01: FIL1
01: USB
04: RTTY
08: RTTY-R
02: FIL2
02: AM
05: FM
17: DV
03: FIL3
Filter setting (
w
) can be skipped with command 01
and 06. In that case, “FIL1” is automatically selected
with command 01, and the default filter setting of the
operating mode is automatically selected with com-
mand 06.
D