10
OTHER FUNCTIONS
10-21
Cmd.
Sub
cmd.
Data
Description
22 00
see p. 10-26 Send/read DV TX data (Up to 30 byte)
01
00
00
Send/read Auto DV RX data output
OFF
01
Send/read Auto DV RX data output ON
01
see p. 10-26 Send/read DV RX data (Up to 30 byte)
02
00, 01
Send/read DV data TX setting
(00=PTT, 01=Auto)
03
00, 01
Send/read DV fast data setting
(00=OFF, 01=ON)
04
00, 01
Send/read GPS Data Speed setting
(00=Slow, 01=Fast)
05
00~10
Send/read TX Delay (PTT) setting
(00=OFF, 01=1 sec. ~ 10=10 sec.)
23 00
see p. 10-26 Read the position
01
00
Send/read the GPS receiver OFF
01
Send/read the internal GPS ON
02
Send/read the external GPS ON
03
Send/read the manually entered
position
02
see p. 10-26 Send/read manually entered position
24 00
00
00
Send/read TX output power setting
OFF
01
Send/read TX output power setting ON
01
00
TX output power setting OFF for
transceive
01
TX output power setting ON for
transceive
Remote jack (CI-V) information (Continued)
*
1
Below 100 Hz is omitted.
*
2
When sending the power ON command (18 01), the
command “FE” must be sent before the basic format.
• 19200bps: 25
• 9600bps: 13
• 4800bps: 7
Example: When sending with 4800 bps
q
w
e
r
t
u
F
F E
×7
A
9
E
F
E
E
1
0
8
1
0
D
F
q
Preamble code (fixed)
w
Transceiver’s default address
e
Controller’s default address
r
Command number
t
Sub command number
u
End of message code (fixed)
*
3
Output setting is automatically turned OFF after turning
OFF the transceiver, then turn it ON again.
Receive frequency setting
Command:
00
,
03
,
05
q
0
X
X
X
X
w
e
X
r
t
X
X
X
0
10 Hz digit: 0, 3, 5, 6 (according to the 100 Hz digit)
1 Hz digit: 0 (Fixed)
1 kHz digit
: 0, 1, 2, 3, 5, 6, 7, 8
100 Hz digit: 0, 2, 3, 5, 6, 7
100 kHz digit: 0 ~ 9
10 kHz digit: 0 ~ 9
10 MHz digit: 0 ~ 9
1 MHz digit: 0 ~ 9
1000 MHz digit: 0 (Fixed)
100 MHz digit: 1, 2, 3, 4, 5
100 Hz digit
10 Hz digit
0
0
2
5
3
3
5
0
6
6
7
5
Operating mode
Command:
01
,
04
,
06
q
X
X
X
X
w
Operating
mode
q
Mode
w
Filter setting
AM
02
01
AM-N
02
02
FM
05
01
FM-N
05
02
DV
17
01
Duplex Frequency offset setting
Command:
0C
,
0D
q
e
w
X
X
X
X
X
X
100 Hz digit
100 kHz digit
10 kHz digit
10 MHz digit
1 kHz digit
1 MHz digit
RF power level setting
Command:
14 0A
LOW
MID
HIGH
0 ~ 84
85 ~ 170
171 ~ 255
External microphone gain setting
Command:
14 0B
1
2
3
4
0000 ~ 0063 0064 ~ 0127 0128 ~ 0191 0192 ~ 0255
Previous view