background image

877 757 8930 

[email protected] | www.icobath.com

Kontour Square Towel Warmer Installation Guide 

Code: K6033E / K6034E / K6035E

24” x 40” Plug-In

FIGURE 1

INSTALLATION INSTRUCTIONS 

(see figure 1)

1.

  Fix wall supports “A” to the wall using the screws provided and in 

locations as shown on figure 2.

2.

    Hang and adjust the towel warmer using set screws “B” to lock stud “C” in 

the wall bracket “A”. Ensure the towel warmer is firmly and safely fixed.

PLUG-IN CONNECTION

TURN OFF POWER SUPPLY BEFORE PROCEEDING
Do not connect the towel warmer to the power supply until all instructions have been read and 
installation carried out in accord with them. Your towel warmer is 150W (110V) and conforms 
to CSA standards (File ref: 2422531). Please ensure the CSA label is visible.

1.

  Turn off power supply.

2.

 Plug connector in.

3.

 Turn on power supply.

1

2

3

ROUGH-IN REQUIREMENTS 

(see figure 2) 

1.

         Check  all  items have been received. 

1. 

Towel Warmer

2. 

Bracket Pack

2.

  Your towel warmer requires 110V GFCI protected power. This 110V receptacle should be located 

no further than 18” from the electric plug-in exit location on the towel warmer (see figure 2), and not 
above the electric plug-in exit location.

3.

  Wall studs or plywood backing is recommended in the wall at all bracket  

locations. See figure 2 for bracket locations.

Warning: In case of damage or failure of the towel warmer the unit should be returned to the manufacturer or their distributor. The 
warranty of 2 years on the towel warmer is NOT VALID in case of improper use or installation. Product is designed for use within Canada 
and the United States only.

Содержание Kontour K6033E

Страница 1: ...ds File ref 2422531 Please ensure the CSA label is visible 1 Turn off power supply 2 Plug connector in 3 Turn on power supply 1 2 3 ROUGH IN REQUIREMENTS see figure 2 1 Check all items have been received 1 Towel Warmer 2 Bracket Pack 2 Your towel warmer requires 110V GFCI protected power This 110V receptacle should be located no further than 18 from the electric plug in exit location on the towel ...

Страница 2: ...lishes steel wool or other cleaning agents be used on this item Specifications Drawings Model Description Finish Weight lb Watts Volts WxH mm WxH Inches Metal Type K6033E Square Electric Plug In Chrome 13 150W 110V 610 x 1015 24 x 40 Stainless Steel K6034E Square Electric Plug In Brushed Nickel 13 150W 110V 610 x 1015 24 x 40 Stainless Steel K6035E Square Electric Plug In Matte Black 13 150W 110V ...

Страница 3: ... lisiblement l étiquette CSA 1 Couper le courant électrique 2 Brancher la fiche 3 Rétablir le courant électrique 1 2 3 REQUIS POUR L INSTALLATION voir la figure 2 1 Vérifier qu il ne manque aucune pièce 1 Sèche serviettes 2 Ensemble de montants de fixation 2 Le sèche serviettes nécessite un courant 110 V et un disjoncteur différentiel de fuite à la terre DDFT La prise 110 V devrait se trouver à 18...

Страница 4: ...LxH pouces Type de métal K6033E Éléments d alimentation électrique Chrome 13 150W 110V 610 x 1015 24 x 40 Acier inoxydable K6034E Éléments d alimentation électrique Nickel Brossé 13 150W 110V 610 x 1015 24 x 40 Acier inoxydable K6035E Éléments d alimentation électrique Noir Mat 13 150W 110V 610 x 1015 24 x 40 Acier inoxydable 877 757 8930 cs icobath com www icobath com Guide d installation du sèch...