Kontour Linear Towel Warmer Installation Guide 

Code: K4023E / K4024E / K4025E

18” x 40” Plug-In

INSTALLATION INSTRUCTIONS 

(see figure 1)

1.

  Fix wall supports “A” to the wall using the screws provided and in 

locations as shown on figure 2.

2.

    Hang and adjust the towel warmer using set screws “B” to lock stud “C” in 

the wall bracket “A”. Ensure the towel warmer is firmly and safely fixed.

PLUG-IN CONNECTION

TURN OFF POWER SUPPLY BEFORE PROCEEDING
Do not connect the towel warmer to the power supply until all instructions have been read and 
installation carried out in accord with them. Your towel warmer is 110W (110V) and conforms 
to CSA standards (File ref: 2422531). Please ensure the CSA label is visible.

1.

  Turn off power supply.

2.

 Plug connector in.

3.

 Turn on power supply.

1

2

3

ROUGH-IN REQUIREMENTS 

(see figure 2) 

1.

         Check  all  items have been received. 

1. 

Towel Warmer

2. 

Bracket Pack

2.

  Your towel warmer requires 110V GFCI protected power. This 110V receptacle should be located 

no further than 18” from the electric plug-in exit location on the towel warmer (see figure 2), and not 
above the electric plug-in exit location.

3.

  Wall studs or plywood backing is recommended in the wall at all bracket  

locations. See figure 2 for bracket locations.

Warning: In case of damage or failure of the towel warmer the unit should be returned to the manufacturer or their distributor. The 
warranty of 2 years on the towel warmer is NOT VALID in case of improper use or installation. Product is designed for use within Canada 
and the United States only.

FIGURE 1

a

c

b

Содержание KONTOUR K4023E

Страница 1: ...2422531 Please ensure the CSA label is visible 1 Turn off power supply 2 Plug connector in 3 Turn on power supply 1 2 3 ROUGH IN REQUIREMENTS see figure 2 1 Check all items have been received 1 Towel Warmer 2 Bracket Pack 2 Your towel warmer requires 110V GFCI protected power This 110V receptacle should be located no further than 18 from the electric plug in exit location on the towel warmer see f...

Страница 2: ...el wool or other cleaning agents be used on this item Specifications Drawings Model Description Finish Weight lb Watts Volts WxH mm WxH Inches Metal Type K4023E Linear Electric Plug In Chrome 7 5 110W 110V 450 x 1000 17 75 x 39 25 Stainless Steel K4024E Linear Electric Plug In Brushed Nickel 7 5 110W 110V 450 x 1000 17 75 x 39 25 Stainless Steel K4025E Linear Electric Plug In Matte Black 7 5 110W ...

Страница 3: ... l étiquette CSA 1 Couper le courant électrique 2 Brancher la fiche 3 Rétablir le courant électrique 1 2 3 REQUIS POUR L INSTALLATION voir la figure 2 1 Vérifier qu il ne manque aucune pièce 1 Sèche serviettes 2 Ensemble de montants de fixation 2 Le sèche serviettes nécessite un courant 110 V et un disjoncteur différentiel de fuite à la terre DDFT La prise 110 V devrait se trouver à 18 po au plus ...

Страница 4: ...Type de métal K4023E Éléments d alimentation électrique Chrome 7 5 110W 110V 450 x 1000 17 75 x 39 25 Acier inoxydable K4024E Éléments d alimentation électrique Nickel Brossé 7 5 110W 110V 450 x 1000 17 75 x 39 25 Acier inoxydable K4025E Éléments d alimentation électrique Noir Mat 7 5 110W 110V 450 x 1000 17 75 x 39 25 Acier inoxydable FIGURE 2 877 757 8930 cs icobath com www icobath com Guide d i...

Отзывы: