10. 

Gently press the lever to dispense the soda 
water. Direct the stream toward the internal 
wall of the drinking glass to avoid excess fizz at 
the top of the glass. 

Note:

 If necessary, you can shake the device again in 

between each glass of water dispensed. This will 
help the gas remain evenly distributed. 

Note:

 Store your pressurized soda siphon in the 

fridge when it’s not actively in use.

CLEANING AND STORAGE

General

  Push down on the lever until the soda siphon is 

completely empty and there is no pressure left. 
Unscrew the head from the siphon.

  Remove the headset and attached straw from 

the bottle.

  Rinse the siphon’s components with clear potable 

water (max. 50°C /122°F) only.

NOTE:

 Never use scouring agents, abrasive 

sponges/brushes, or sharp objects to clean the  
siphon. This will void your warranty and likely 
damage the siphon. 

NOTE:

 Do not put your soda siphon in the dishwasher 

and do not wash in boiling water.

Service

  Spare parts can be purchased individually from 

www.icotrading.com

  If you think there is something wrong with your 

siphon, please contact us so we can check the 
device’s operation.

Storage

  If your ICO Soda Siphon is not going to be filled 

again immediately, leave the components to air 
dry in a clean place and store it in a dismantled 
condition without the head screwed on. Rinse the 
device thoroughly before using again. 

Troubleshooting

To release the pressure in your soda siphon

Place the siphon upright in a sink and gently push 
down on the lever until the pressure is gone from the 
siphon (there is no gas or water leaving the device). 
Now the head can be safely removed from the 
bottle. If the pressure will not release, please contact 
us at 

www.icotrading.co.uk.

Soda charger will not puncture

1.

  The charger being used is not suitable: we recom-

mend only using ICO brand 8g Co2 chargers.

2.

 The charger was inserted backwards: flip the 

charger around and attempt to puncture the 
charger again.

3.

 The puncturing unit has been damaged or is 

clogged: contact us at www.icotrading.co.uk to 
arrange a service.

Water does not carbonate (remains still)

1.

 The siphon was not shaken enough: shake the 

siphon vigorously several times (at least 5 times) 
before attempting to dispense.

2.

 The water is not cold enough: The colder the 

water, the more Co2 it can absorb. For the best 
results we recommend keeping your filled soda 
siphon in your fridge when not in use.

INSTRUCTION 

MANUAL FOR ICO011 1L ALUMINIUM

SODA

 

SIPHON

3

Содержание ICO011

Страница 1: ...e same device type don t use a whipped cream dispenser head on your soda siphon for example Never combine parts of your ICO soda siphon with parts produced by other manufacturers Never attach the device head so that it is crooked Never lean your body over the device when screwing in the charger Never unscrew the device head from a pressur ized device Do not heat the device when in use or for clean...

Страница 2: ...add any extra ingredients or flavours The colder the water the more carbonation will occur Charging 4 Insert the tube and gasket into the headset 5 Firmly screw the headset onto the bottle of your soda siphon 6 Insert 1 ICO soda charger 8g Co2 only do not use N2O into the charger holder 7 Screw the charger holder with the inserted soda charger onto the headset until you hear all the gas has entere...

Страница 3: ...rage If your ICO Soda Siphon is not going to be filled again immediately leave the components to air dry in a clean place and store it in a dismantled condition without the head screwed on Rinse the device thoroughly before using again Troubleshooting To release the pressure in your soda siphon Place the siphon upright in a sink and gently push down on the lever until the pressure is gone from the...

Страница 4: ...refill the siphon using only one charger During operation gas but no water is leaking between the bottle and the head 1 The head was not tightened securely tighten the head onto the bottle by hand as per the instruc tions 2 The gasket has been damaged contact ICO to arrange a service How to Contact Us If you need any assistance using your device please email us at info icotrading net Alternatively...

Отзывы: