Important Safety Information
Input:
Input:
•
Voltage:
Millivolt to 30 VAC/VDC
•
Voltage:
18-30 VAC
•
DC Power:
3 volts (2 “AA” alkaline batteries included)
Output:
•
Maximum:
1 amp per terminal (3 amp total for all terminals)
•
Temperature control ranges:
45°F to 90°F
Accuracy:
± 1°F
•
Differential range:
1°F to 3°F
•
System configurations:
Single-stage heat, single-stage cool
or single-stage heat pump, gas, oil,
electric
•
Terminations (SC2000):
RC, RH, W, Y, O, B, G
•
Terminations (SC2001):
R, W, Y, O, B, G, C
SET
ROOM
LO BAT
DIFF
Low battery signal
Temperature
differential setting
Room temperature
Room temperature
setpoint
• Always turn off the thermostat before installing, removing, cleaning, or servicing; turn off the power at
the main power source by unscrewing fuse or switching off circuit breaker
• Do not switch to “Cool” if room temperature is below 50°F; this could damage your A/C system and
cause injury
• Do not install on voltages higher that 30 VAC
• All wiring must conform to local and national building and electrical codes and ordinances
• While cleaning, do not get soap directly on thermostat switches or LCD readout; only use a damp cloth
with a mild soap to wipe outside of thermostat cover
Specifications
SC2000
SC2001