458DUO
Dual Balance Charger/Discharger/DC Power
- 24 -
When charging the over-discharged battery, the charger will detect if the cell voltage is larger than the
Restore Lowest
Voltage
, if larger, it will pre-charge the battery with
Restore Charge Current
, if within the setting
Restore Charge Time
,
the cell voltage rises to the normal value then it will turn to the charging program; otherwise it will stop running.
Pb Battery Discharge Setup
Select
Program
→
Discharge
to
enter
PB DISCHARGE SETUP
interface.
See details about setting on LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Setup.
Pb Battery Cycle Setup
Select
Program
→
Cycle
to enter
PB CYCLE SETUP
interface.
See details about setting on LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Cycle Setup.
Digital Power Supply Setup
458DUO can be an adjustable and stabilized digital power supply, setting as below:
After adding program, it will switch to
Power
in
Type
option on the
MEMORY SETUP
interface. After editing all
parameters for program, click "
Save
" to save and return to the previous interface.
Restore Lowest Voltage:
0.5V/Cell-2.5V/Cell; default: 1V/Cell
Restore Charge Time:
1Min-5Min; default: 3Min
Restore Charge Current:
0.02A-0.5A; default: 0.1A
1.Lock
:
The parameters can’t be modified when running program
2.Auto start:
If run this program when power off, then the
program will run automatically when power on again
3.Live update:
The modified parameters will take effect when
running program
4.Voltage:
2V- 36.5V
;
default: 5V
5.Current:
1A-45A
;
default: 22.5A