background image

456DUO 

 

  Dual  Balance  Charger/Discharger/DC  Power

 

 

- 19 - 

         

 

 

 

 

 

 

1. 

Accelerated storage

: accelerated storage via internal resistance correction. Tick 

Accelerated storage

 to activate 

accelerated storage. 

2. 

Storage Compensation

 is the compensation for the battery voltage fallback: 

    

for storage charge, the actual storage voltage=Storage Cell V Storage Compensation; 

    

for storage discharge, the actual storage voltage=Storage Cell Voltage - Storage Compensation. 

LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Setup 

Select 

Program

Discharge

 to enter 

Discharge setup

 interface. 

         

 

 

 

 

 

 

 

 

1. The charger first discharges with constant current (CC) according to the user setting then turns to constant voltage 

(CV) when it reaches the discharge voltage. In the CV phase the current gradually falls, and the charger will terminate 

discharging when the current falls below the percentage of the configured discharge current. 

2. 

Regenerative mode

 has three available settings: 

OFF

To input

To channel

, see more details on 

Important Notes

 

Regenerative To Input 

When selecting to 

To input

 

on 

Regenerative Mode

, the energy discharged by the charger to the battery will be recovered to 

the input port. For parameter settings, see 

Input Limit Setup

 

 

Regenerative To Channel 

When  selecting  to 

To  channel

 

on 

Regenerative Mode

, “

Set…

"button changes  from inactive  to  its  operational status,  and 

click to enter 

CHANNEL REGENERATIVE SETUP

 interface. 

Storage Cell Voltage:

   

LiPo  

3.7V/Cell-3.9V/Cell; default

3.85V/Cell 

LiIo  

3.6V/Cell-3.8V/Cell; default

3.75V/Cell 

LiFe  

3.1V/Cell-3.4V/Cell; default

3.30V/Cell 

LiHV   

3.75V/Cell-4.1V/Cell; default

3.9V/Cell 

LTO   

2.4V/Cell-2.6V/Cell; default

2.5V/Cell 

User   

1.00V/Cell-4.5V/Cell; default

1.0V/Cell 

Storage Compensation:   

0V/Cell-0.2V/Cell;    Default: 0.01V/Cell 

 

 

 

Discharge Current:

 

0.05A-45A; default: 2A

 

Discharge Voltage

:   

LiPo   

3V/Cell-4.1V/Cell

default

3.5V/Cell 

LiIo   

2.5V/Cell-4.0V/Cell

default

3.5V/Cell 

LiFe   

2V/Cell-3.5V/Cell

default

2.5V/Cell 

LiHV   

3V/Cell-4.25V/Cell

default

3.6V/Cell 

LTO   

1.5V/Cell-2.9V/Cell

default

1.8V/Cell 

NiZn   

0.9V/Cell-1.6V/Cell

default

1.1V/Cell 

User   

0.5V/Cell-4.5V/Cell

default

1.0V/Cell 

End Current

1%-100%; default: 50% 

Regenerative Mode:

   

OFF (default), To input, To channel 

Содержание 456DUO

Страница 1: ...m 14 Error Messages 14 Monitor Settings 14 Internal Resistance Measurement 14 USB SD Card Use 15 Setup of Different Batteries 15 LiPo LiIo LiFe LiHV LTO NiZn User Setup 16 LiPo LiIo LiFe LiHV LTO NiZn...

Страница 2: ...onfiguration Setup 28 Language Setup 28 Calibration 29 Extra Function 30 Log Files Manage 30 Servo Test 30 Pulse Measurement 32 Junsi Console for 456DUO 33 Firmware Upgrades 34 Firmware Upgrades via J...

Страница 3: ...he charger unsupervised when charging or discharging If you leave disconnect the battery and switch off charger to prevent any unexpected dangers or damage 3 Ensure the charger program and settings ma...

Страница 4: ...and 1 15s Pb batteries 15 With digital power mode for great protection over current protection over voltage protection input under voltage protection input undercurrent protection and etc 16 With typ...

Страница 5: ...V 3A 9V 2A 12V 1 5A Support Battery type LiPo Lilo LiFe LiVH LTO NiZn NiMH NiCd Pb Net weight 920g Dimension 171 118 57 0 5mm Warranty Service 1 The product from the date of purchase enjoys free repai...

Страница 6: ...7 CH1 Balance port 08 CH 2 Output port 09 CH 2 Multi function port 10 CH2 Balance port 11 LCD 12 Rotary switch 13 STATUS 1 14 STOP START 1 15 TAB SYS 16 STATUS 2 17 STOP START 2 There are 3 functions...

Страница 7: ...ual Software CD ROM EC8 10AWG 600mm XT90H F 2pcs cd rom resources download http www hillrc com cd_rom zip OptionalAccessories Temperature sensor Output cable 350mm XT90 12AWG 300mm Balance connector c...

Страница 8: ...return to Previous Menu STATUS x Click STATUS x Program runtime Switch the display information page of CH x channel STATUS x Press STATUS x for 2 seconds Initial interface Start internal resistance m...

Страница 9: ...o select Synchronous In this mode the maximum current can be up to 70A power capacity is the sum of both channels limits At the same time it is limited to the maximum power of 2200W In the synchronous...

Страница 10: ...change the input source type while pressing any other buttons to enter the initial interface There are different parameter setting of these four types of power supply the user can set in SYSTEM MENU...

Страница 11: ...can set or modify the program on this interface 1 When editing the memory name Turn to select the character press to confirm the selected character long press TAB SYS to delete the character Press aft...

Страница 12: ...nning program as below 1 The revised common parameters of built in program will be saved by default automatically after running while the program customized by the user can be set to be saved or not i...

Страница 13: ...ance 2 Pack internal resistance 3 Line resistance Information page 1 Power 2 End voltage 3 Lowest input voltage 4 Safety time 5 Temp cutoff 6 End charge capacity Cycle charge information 1 Cycle charg...

Страница 14: ...d dialog box and the buzzer alarms as below Monitor Settings Press STATUS x STOP START x at the same time for 2 seconds under initial interface it will pop up blow window Press Start button to start M...

Страница 15: ...r exFAT 2 Data in SD card needs to be backed up in case it is lost Setup of Different Batteries The following form shows specific range of different batteries Nominal voltage Charge voltage Discharge...

Страница 16: ...he user changes the values the battery types and cells voltage value on the main charging interface will be displayed alternately 2 For the setting process for all program in this manual tick Show to...

Страница 17: ...y When switch to User Balance mode on Chg Mode the Balance Diff Balance Set Point Balance Over Charge and Balance Done Delay are available after setting click Back to return to the previous interface...

Страница 18: ...e external temperature sensor detects the set value the program will stop running in order to protect the battery from being damaged by high temperature LiPo LiIo LiFe LiHV LTO User Storage Setup This...

Страница 19: ...ant Notes Regenerative To Input When selecting to To input on Regenerative Mode the energy discharged by the charger to the battery will be recovered to the input port For parameter settings see Input...

Страница 20: ...ge when discharge enters the CV phase it starts to balance the cell voltages LiPo LiIo LiFe LiHV LTO NiZn User Discharge Safety Setup Click Safety to enter DISCHARGE SAFETY SETUP interface LiPo LiIo L...

Страница 21: ...456DUO Dual Balance Charger Discharger DC Power 21 Balance Only is the program only to equalize the individual cells through balance port to reduce the voltage difference...

Страница 22: ...NiCd Battery Charge Advanced Setup Click Advanced to enter CHARGE OPTION SETUP interface For the over discharged NiMH NiCd battery the voltage may be close to 0V tick Allow 0V Charging to allow charg...

Страница 23: ...modes Charge Discharge and Cycle Pb Battery Charge Setup Select Program Charge to enter PB CHARGE SETUP interface 1 The charger first charges with constant current CC according to the user setting th...

Страница 24: ...interface See details about setting on LiPo LiIo LiFe LiHV LTO NiZn User Cycle Setup Digital Power Supply Setup 456DUO can be an adjustable and stabilized digital power supply setting as below After a...

Страница 25: ...mperature exceeds the Power Reduce temperature the charger will stop increasing temp shown in orange by reducing the highest power limit When the temperature reaches Shut Down temperature the charger...

Страница 26: ...sequence number 5 above LCD Setup Select SYSTEM MENU LCD Screen to enter the setup interface USB PD Setup Select SYSTEM MENU USB PD to enter the setup interface Output Power Setup Select SYSTEM MENU...

Страница 27: ...ing click Save to save and return to the previous interface After ticking Regenerative enable if run the regenerative discharge to input the electrical discharged will be re charged as the battery of...

Страница 28: ...U and enter the setup interface 1 Users can Save Configuration To SD card and re load via the SD card if needed 2 After loading the configuration files in addition to Calibration Select it will cover...

Страница 29: ...r select User Calibration the User Calibration option changes to active status If the user selects User Calibration the corresponding message will appear in the interface after booting the charger as...

Страница 30: ...And select Delete All to delete all Servo Test Connect the servo with the multifunctional port like below but pay attention that the port can t provide voltage for the servo and it needs connect exte...

Страница 31: ...st Liner Test When turning the knob the pointer deflects with the setting value of Step and the servo responds accordingly Fixed Point Test When turning the knob the pointer deflects among each settin...

Страница 32: ...like below which can measure their pulse signal Select SYSTEM MENU Pulse Test to enter the pulse test interface only CH 1 J1 port supports the input signal of Pulse Measurement S S Signal Receiver or...

Страница 33: ...tall Note 456DUO enabled third party software Data Explorer http www nongnu org dataexplorer download html 1 Connect 456DUO with PC via USB port make sure USB driver has been installed and run the sof...

Страница 34: ...onnect the power supply of the charger After hearing a beep sound release the button If the charger fails to start normally ex Unexpected power outage please enter the Boot mode again it will repeat t...

Страница 35: ...harge Chg Mode to select Reflex mode which is when the power supply for the charger acts as battery power the charger will regenerative charge for battery power during the process to discharge the bat...

Страница 36: ...power capacity External capacity resistance s setting R Vbat Iset P Vbat Iset R The value of the external capacity resistance P Rating capacity of the external capacity resistance Vbat Battery voltag...

Страница 37: ...T Waiting status PRE_C Pre charge program will pre charge when the cell voltage is too low CY_DE Cycle delay status KEEP Keep charging status keep charging for a while after setting pre charge OVER Ov...

Страница 38: ...fe temperature range Safe temperature range is exceeded 20XX Output connection broken Output connection is broken 21XX Balance port connection error Balance port has a connection error 22XX Low cell v...

Отзывы: