![ICETEAM 1927 SL193-011342 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/iceteam-1927/sl193-011342/sl193-011342_electronic-manual_3397416046.webp)
SL193-011342 ED00 10-2018
43
HOT CALIBRATION
To calibrate the machine, it is necessary to set a Set HOT of 120 (see user programming).
Fill the cylinder with the mix and select PRODUCTION.
Check with a current probe the absorption of the corresponding beater motor.
On the page regarding the HOT display a number will be shown that will be increasing.
When the cylinder reaches the texture (HOT =120) the current read by the probe must be
equal to the value of the beater motor. If it is higher, set a higher "TRIMMER HOT", if it is lower,
set a lower "TRIMMER HOT", (programming on step Trimmer HOT).
Repeat the process until this value of the motor corresponds to HOT = 120.
Valid for both sides.
ATTENTION: DO NOT EXCEED THE NOMINAL ABSORPTION OF THE MOTOR PLATE.
Содержание SL193-011342
Страница 1: ...Electronic Manual English Version Ed00 10 2018 SL193 011342 P1...
Страница 2: ......
Страница 4: ...File name SW version Date Changes to previous version P1 1_00 mot 1_00 22 10 2018 First version...
Страница 6: ...XIX C Ohm table 48 XX Sensor calibration after electronic board replacement 50...
Страница 12: ...SL193 011342 ED00 10 2018 9 Figure 3 PR Left Side PR EVRC TEC EVRC TEV EVRC Figure 4 5 TEC TEV...
Страница 38: ...SL193 011342 ED00 10 2018 35 Step Contents U14 Wash hour Setting of display hour of the Wash today alarm...
Страница 52: ...SL193 011342 ED00 10 2018 49 85 1508 90 1557 9 95 1608 7 100 1660 4 105 1713 110 1766 5 115 1820 9...
Страница 57: ...REALIZED by VERIFIED by APPROVED by Francesco Curatolo Francesco Curatolo Salvador Carbonell Salvador Carbonell...
Страница 58: ......