Programming Table (FOR TECHNICIANS)
The technician can change some machine parameters. To access the Technical
Programming, press STOP and STORAGE at the same time and keep pressed for 10". On this
point, the display shows:
The display will show the first step of the Technical Programming. The first line refers to the
description and the second line to the step number (T=Technician) and to the value. Press the
INCREASE or DECREASE keys to change the value. STOP to access the following step. See
programming table. To exit the programming do not p
ress any key for 30’’
or keep pressed
PRODUCTION or CLEANING.
Step
Contents
T03
Hysteresis Hot
A minimum value turns the HOT more sensitive during the extraction.
When the machine is in PRODUCTION and MIR excited, after a decoupling
of the compressor by HOT, the compressor reactivates when the consistency
indication appearing on the display is lower than the HOT less the value set
for this step.
T05
Hot gas
HOT gas electro-valve excitation time (EVRC). Whenever EVFC
deactivates, the EVRC activates for the set time in this step. Programmable
in tenths of second.
T07
Beater delay
The time in which the beater continues to operate after having reached
Hot, in PRODUCTION or the temperature, in STORAGE.
T09
Block Hot
In PRODUCTION, in cooling of cylinder, if the pre-set time in step Timeout
prd. (T16) expires without having reached the set HOT:
-
If HOT > Block Hot the TimeOut Production alarm is displayed.
-
If HOT < Block Hot, the TimeOut Production alarm is displayed and
the machines passes on to STOP.
14:10:22 Mon
*******PROG*******
Содержание SL193-011342
Страница 1: ...Electronic Manual English Version Ed00 10 2018 SL193 011342 P1...
Страница 2: ......
Страница 4: ...File name SW version Date Changes to previous version P1 1_00 mot 1_00 22 10 2018 First version...
Страница 6: ...XIX C Ohm table 48 XX Sensor calibration after electronic board replacement 50...
Страница 12: ...SL193 011342 ED00 10 2018 9 Figure 3 PR Left Side PR EVRC TEC EVRC TEV EVRC Figure 4 5 TEC TEV...
Страница 38: ...SL193 011342 ED00 10 2018 35 Step Contents U14 Wash hour Setting of display hour of the Wash today alarm...
Страница 52: ...SL193 011342 ED00 10 2018 49 85 1508 90 1557 9 95 1608 7 100 1660 4 105 1713 110 1766 5 115 1820 9...
Страница 57: ...REALIZED by VERIFIED by APPROVED by Francesco Curatolo Francesco Curatolo Salvador Carbonell Salvador Carbonell...
Страница 58: ......