background image

1.Safety Information

 

 

 

 

1.

 

Safety Information   

Safety Considerations 

Before any operations, please read the following safety precautions to avoid any 

possible bodily injury and prevent damage  to  this product or any other products 

connected. To avoid any contingent danger, use this product only as specified.   

 

 

Limit operation to the specified measurement category, voltage, or amperage ratings. 

 

Do not use the multimeter if it is damaged.

 Before you use the multimeter, inspect 

the case. Look for cracks or missing plastic. Pay particular attention to the insulation 

surrounding the connectors.   

 

Do not use the test leads provided for other products.

 Use only the certified test 

leads specified for this product. 

 

Inspect the test leads for damaged insulation or exposed metal. 

 

Before use, verify the multimeter's operation by measuring a known voltage.   

 

Only the qualified technicians can implement the maintenance.   

 

Always use the specified battery type. 

The power for the multimeter is supplied with 

two standard AA 1.5 V batteries. Observe the correct polarity markings before you 

insert the batteries to ensure proper insertion of the batteries in the multimeter.

 

 

Check  all Terminal Ratings. 

To avoid fire or shock hazard,  check  all  ratings  and 

markers of this product. Refer  to  the user's manual for more information about 

ratings before connecting to the multimeter.   

 

Do not operate the multimeter with the cover or portions of the cover removed or 

loosened. 

 

Use Proper Fuse. 

Use only the specified type and rating fuse for the multimeter.   

 

Do not operate  if in any doubt. 

If you suspect damage occurs to the multimeter, 

have it inspected by qualified service personnel before further operations.   

 

To avoid electric shock, do not operate this product in wet or damp conditions. 

 

Do not operate in an explosive atmosphere.   

 

Keep product surfaces clean and dry. 

 

Do not apply more than the rated voltage (as marked on the multimeter) between 

terminals, or between terminal and earth ground. 

 

When measuring current, turn  off the circuit power before connecting the 

multimeter in the circuit. Remember to place the multimeter in series with the 

circuit.   

 

When servicing the multimeter, use only the specified replacement parts. 

 

Use caution when working above 60 V DC, 30 V AC RMS, or 42.4 V peak. Such 

voltages pose a shock hazard.   

Содержание MD-6000

Страница 1: ...MANUAL DE INSTRU ES DO MULT METRO DIGITAL MODELO MD 6 Manual em ingl s Leia atentamente as instru es contidas neste manual antes de iniciar o uso do instrumento...

Страница 2: ...leep Mode 7 Backlight Control 7 Selecting the Range 8 Multimeter in Brief 8 Front panel 8 Rotary switch 9 Keypad 9 Display screen 10 Input terminals 12 4 Making Measurements 13 Measuring AC or DC Volt...

Страница 3: ...Measurements 17 Buzzer Feature 18 6 Bluetooth Function 19 How to Connect 19 User Interface 21 Operations 22 7 Technical Specifications 24 8 Appendix 26 Appendix A Enclosure 26 Appendix B General Care...

Страница 4: ...markings before you insert the batteries to ensure proper insertion of the batteries in the multimeter Check all Terminal Ratings To avoid fire or shock hazard check all ratings and markers of this p...

Страница 5: ...tors before testing resistance continuity diodes or capacitance Use the proper terminals function and range for your measurements When the range of the value to be measured is unknown set the rotary s...

Страница 6: ...to protect against transients from energy consuming equipment supplied from the fixed installation such as TVs PCs portable tools and other household circuits Measurement CAT III applies to protect a...

Страница 7: ...tely happen Warning It indicates an injury or hazard may be accessible potentially Caution It indicates a potential damage to the instrument or other property might occur Safety Symbols Symbols on the...

Страница 8: ...MD 6 0 0 0...

Страница 9: ...6 digit reading achieving higher measurement accuracy than 1 3 2 or 3 3 4 digit counterparts Larger display easier data reading analog bar graph is displayed synchronously Multi connection more than...

Страница 10: ...appearance of the instrument or the instrument can not work normally or fails in the performance test please get in touch with the ICEL s distributor responsible for this business or the ICEL s local...

Страница 11: ...F the multimeter turn the rotary switch to the position Sleep Mode The multimeter automatically enters the sleep mode if the rotary switch is not moved or a key is not pressed for 15 minutes When the...

Страница 12: ...additional press of sets the multimeter to the next higher range unless it is already in the highest range at which point the range switches to the lowest range When manual range is enabled press for...

Страница 13: ...Capacitance measurement Page 14 Diode test Page 14 Resistance measurement Page 13 Frequency measurement Page 15 Transistor measurement Page 15 Temperature measurement Page 15 DC or AC current measurem...

Страница 14: ...ge 7 Data Hold Page 17 Relative Measurements Page 17 Bluetooth Page 19 Display screen Figure 3 2 Display screen Symbol Description Details Bluetooth enabled Page 19 Auto range Page 8 Maximum reading P...

Страница 15: ...units Page 11 Analog bar graph Measurement units Sign Description M Mega 1E 06 1000000 k kilo 1E 03 1000 m milli 1E 03 0 001 micro 1E 06 0 000001 n nano 1E 09 0 000000001 Sign Description Measurement...

Страница 16: ...t observe the rotary switch position of the multimeter and then connect the test leads to the correct terminals Caution To avoid damaging the multimeter do not exceed the rated input limit Rotary swit...

Страница 17: ...V 1 Rotate the rotary switch to or Default is DC measurement mode will be displayed Press to switch into AC measurement mode will be displayed 2 Connect the black test lead to the terminal and the re...

Страница 18: ...esting for Continuity Caution To avoid possible damage to your multimeter or to the equipment under test disconnect the circuit power and discharge all high voltage capacitors before testing for conti...

Страница 19: ...oints and read the display 4 Press to switch between the frequency and duty cycle measurements When measuring AC voltage or AC current press to cycle through frequency measuring duty cycle measuring a...

Страница 20: ...voltage capacitors 2 Connect the black test lead to the terminal For currents below 600 mA connect the red test lead to the terminal for currents within 600 mA 20 A connect the red test lead to the te...

Страница 21: ...f function is disabled Note This function is not available when measuring diodes capacitance transistor and frequency Making Relative Measurements When making relative measurements reading is the diff...

Страница 22: ...additional press of sets the multimeter to the next higher range unless it is already in the highest range at which point the range switches to the lowest range When manual range is enabled press for...

Страница 23: ...efore turning off the buzzer will sound BeBe two times System Requirements of Mobile Devices Android devices with Bluetooth connectivity Android Versions 4 0 and above for the version 4 0 below some f...

Страница 24: ...f the screen to launch device connection 5 If the Bluetooth function is activated skip this step if not a dialog box will ask whether to turn on Bluetooth Click Yes Click to scan for Bluetooth devices...

Страница 25: ...name Click to enter Single View Add Next page Single view Graph Table Exit About Single View Single View Range Data Hold Relative Measurement Function Details follow Click to disconnect Press hold to...

Страница 26: ...device the name is still the default one or the customized name to the connected device Add meter In double view click softkey Select meter In single or double view click or softkey Disconnect meter I...

Страница 27: ...the displayed data into CSV file Share Share the measurements via the installed sharing apps Clear data Clear the data displayed Setting Sampling Interval Set the interval of sampling unit second Fil...

Страница 28: ...6 000A 0 01 mA 0 8 2dig A 20 00A 1 1 mA 2 3dig Resistance 600 0 6 000k 60 00k 600 0k 6 000M 10 00M 0 1 0 8 2dig 60 00M 0 01 M 2 3dig Capacitance F 40 00nF 0 01 nF 2 5 3dig 400 0nF 4 000 F 40 00 F 0 1...

Страница 29: ...e RMS The model with T has this function Diodes Test Measuring Transistor Sleep Mode Continuity Test Low battery indication The is displayed when the battery is under the proper operation range Data H...

Страница 30: ...the dust from the instrument surface with a soft cloth Do not make any scuffing on the screen when clean the LCD Clean the instrument with a wet soft cloth not dripping water It is recommended to scr...

Страница 31: ...and any connectors from the input terminals 2 Lift the tilt stand and loosen the screws with a suitable Phillips screwdriver and remove the battery cover 3 Pry the fuse cover open using a straight sc...

Страница 32: ...www icel manaus com br icel icel manaus com br...

Отзывы: