background image

JP30/40/50

If there are any problems, please email us:

offi[email protected]

Содержание GO12

Страница 1: ...JP30 40 50 If there are any problems please email us o cial icecofreezer com...

Страница 2: ......

Страница 3: ...Catalogue 1 1 What s Inside 2 2 Operation 3 5 Care And Maintenance 4 6 Error Codes Solutions 5 8 Warranty Return Policy 6 9 Troubleshooting Q A 7 14 Safety Instructions...

Страница 4: ...What s Inside Refrigerator x1 Insulated Protective Cover x1 12 24V DC Cigarette Lighter Plug Cable x1 12 Feet Cigarette Extension Cable x1 01 1 110V AC Wall Outlet Cable x1 Wired Basket x1...

Страница 5: ...Operation 2 A Power Press Hold to turn on o B Compressor Speed MAX ECO Mode C Temp Setting DOWN D Temp Setting UP 02...

Страница 6: ...ned on Press Hold A Power Button you can press the MAX ECO Button B to toggle between MAX or ECO compressor speed for the fridge 03 2 2 Switch Between C to F With the unit turned on press and hold C D...

Страница 7: ...04 2 4 Triple Battery Protection Operation Push the triple battery protection button up and down to adjust the HIGH MED or LOW gear NOTE Details of Battery Protection Mode could be found in Page 11...

Страница 8: ...nterior and exterior of your fridge 3 2 DOs and DON Ts Please power o and unplug the unit before cleaning Please use non abrasive detergent to cleaning the interior exterior of the fridge Please don t...

Страница 9: ...ystem is too high E3 Minimum motor speed error The compressor overloads and the motor can not maintain its minimun speed 1850 rpms E4 Thermal cut out of electronic unit Thermal cut out error If the re...

Страница 10: ...on certain vehicles due to small wiring imperfections contributing to a measured DC voltage drop at compressor start up Lowering the battery protection setting may resolve this issue Please also try t...

Страница 11: ...be returned in the original condition and packaging Thank you for your cooperation If the product is received damaged or defective during transportation you need to contact our customer service withi...

Страница 12: ...istance ICECO refrigerators can operate under light rain conditions Please keep the vents above clear of water and please add some clearances to the bottom of the fridge if the ground is wet Weather P...

Страница 13: ...el Insulation Test JP30 JP40 JP50 Ambient temperature of 25 C 77 F refrigerator temperature from 18 C 0 F to 20 C 68 F needs 3 4 5 hours on average 3 Why did it change back to the original temperature...

Страница 14: ...n operation abnormalities 5 What is the function of triple battery protection How do they work The triple battery protection is designed to prevent over discharge and battery depletion When the measur...

Страница 15: ...attery voltage reaches 10 9 volts the refrigerator will start again 6 What is the power draw in max fast cooling mode Model Electrical Power GO12 50W Model Electrical Power JP42 55W GO20 50W VL35 Seri...

Страница 16: ...What is the speci cation of the fuse of the refrigerator The supply line is protected by a 15A fuse located in the refrigerator Because of the sinking nature of cold air di erent temperatures may exi...

Страница 17: ...he safety instructions the manufacturer cannot be held responsible for the damage The use of accessories that are not recommended by manufacturer can cause injuries and will invalidate any warranty th...

Страница 18: ...cooling o Place arrange the content of your fridge securely when using the refrigerator inside a moving vehicle To maximize energy savings please make sure the lid is closed and secure and only open...

Страница 19: ...er Do not use electrical devices inside the food storage compartments of the appliance unless approved recommended by the manufacturer Do not store explosive items such as aerosol cans with a ammable...

Страница 20: ...technical data label inside the product 1 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge...

Страница 21: ...atering and similar non retail applications 4 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly quali ed person in order to avoid a hazard 5 Do not s...

Страница 22: ......

Страница 23: ......

Страница 24: ...Cooler Than A Cooler...

Отзывы: