background image

SAFETY PRECAUTION 

2

ICE IM3

           OPERATOR

Carefully read and understand this manual before operating this machine.

This machine must be grounded!

This  machine shall be grounded while in use to protect theoperator from electric shock.

grounding provides a path of least resistance for electric current. This machine is equipped 

with a cord having an equipment-grounding conductor

 

and grounding plug. The plug must be 

plugged into an appropriate outlet that is properly installed and grounded in accordance with all 

local codes and ordinances. Do not remove the ground pin under any circumstances.

This machine is for use on a nominal 220-volt circuit 

and has a grounding plug that resembles the plug 

illustrated in Figure. Make sure that the machine is 

connected to an outlet having the same configuration as 

the plug. No adapter should be used with this machine.

This machine is intended for commercial use. It is constructed for use in an indoor environment 

and is nor intended for any other use. Use only recommended accessories.

1. Do not operate machine:

– Unless trained and authorized.

– Unless you have read and

– In flammable or explosive areas.

understand the operators manual.

– With a damaged cord or plug

– With the use of extension cords.

– If not in proper operating condition.

– In outdoor areas and standing water.

2. Before operating machine:

– Make sure all safety devices are in place and operating properly.

3. When using machine:

– Do not run machine over cord.

– Do not pull machine by cord or plug.

– Do not pull cord around

– Do not unplug by pulling on the cord.

sharp edges or corners.

– Do not stretch cord.

– Do not handle plug with wet hands.

– Keep cord away from heated surfaces.

– Report machine damage or faulty

operation immediately.

T

o avoid electrical shock,please replace the power cord immediately if any damage is 

being detected. The replacement must be performed only by an authorized person or 

by our customer service center. 

4. Before leaving or servicing machine:
– Turn off machine.

– Unplug cord from outlet.

5. When servicing machine:
– Unplug cord from outlet.

– Use manufacturer supplied or

approved replacement parts.

Содержание IM3

Страница 1: ...Operator Parts Manual Three Speed Air Mover www icecompanies com 6010151 REV 02 06 2012 IM3 INTERNATIONAL CLEANING EQUIPMENT ...

Страница 2: ...N 2 MACHINE OPERATION Storage 3 MACHINE COMPONENTS 4 PARTS LIST 5 7 SAFETY PRECAUTION In Chinese 8 Machine OPERATON Storage In Chinese 8 SPECIFICATIONS 9 Wiring Diagram 10 WEAR TEAR PARTS 11 ICE IM3 1 TABLE OF CONTENTS ...

Страница 3: ...ment and is nor intended for any other use Use only recommended accessories 1 Do not operate machine Unless trained and authorized Unless you have read and In flammable or explosive areas understand the operators manual With a damaged cord or plug With the use of extension cords If not in proper operating condition In outdoor areas and standing water 2 Before operating machine Make sure all safety...

Страница 4: ...ng well for many years please follow the following maintenance procedures Always confirm that the machine is unplugged prior to performing any maintenance or repairs 1 Unplug machine as soon as you are done using it 2 Wrap the power cord around the telescoping transport handle 3 Check power cord for any damage If any damage is detected replace the cord immediately 4 Lubricate wheels with a water r...

Страница 5: ...INE COMPONENTS 4 ICE IM3 OPERATOR 1 Telescoping handle 2 Right net intake 3 Rubber stand 4 5 Wheel 5 Isolate foot 6 Front prop 7 Finger guard 8 Housing 9 Left net intake 10 Power switch 3 8 7 6 9 1 4 2 5 10 ...

Страница 6: ...ICE IM3 5 OPERATOR ...

Страница 7: ...14405 Screw Fh 8 8 5 32 32 8 2 13 6010147 Panel Switch 1 14 1323210 Screw Ph ST4 2X9 5 4 15 6010131 Label Switch 1 16 6010132 Switch 1 17 1662518 Rivet 4 8X18 4 18 4010316 Logo 1 19 1412309 Washer Plain 3 4X 9X0 8 8 20 1421512 Washer Plain 5X 12X1 5 11 21 6010107 Block Stand Right Front 1 22 6010114 Net Vent Outlet 1 23 6010109 Rubber Block Stand 2 24 6010110 Stand 1 25 6010108 Block Stand Left Fr...

Страница 8: ...Nut Lock M5 2 39 1221420 Screw Ph M4 X20 1 40 1221515 Screw Ph M5 X15 2 41 6010133 Capacitor 20uF 450V 1 42 1113304 Kep Nuts 3 43 6010125 Clamp Capacitor 1 44 6010150 Serial Decal 1 45 6010144 Warning Decal 1 46 6010134 Telescoping Handle 1 47 1221520 Screw Ph M5 X20 1 48 1422300 Washer Lock Φ3 2 49 1221314 Screw Ph M3 X14 2 50 2320403 Strain Relief 1 51 6010142 Power Cord 1 52 6010140 Plate Chamb...

Страница 9: ...3 Voltage 220V Power 0 75HP 550W thermally protected Current 4 2 A Frequency 50Hz Fan size 9 5 24 1cm Speed 3 RPM Flow Rate 850 L 2200CFM 950 M 2600CFM 1150 H 3200CFM Dimensions 55 4cm L X46 5cm W X52 2cm H Weight 16kg Length of Power cord 6 5m ...

Страница 10: ...10 ICE IM3 OPERATOR Wiring Diagram IM3 G Y Brown Blue 50 60Hz Phase Power Single 220V Supply Power Supply RVV 3X1 0 Cord Yellow Green Red Black Brown Capacitor Brown ...

Страница 11: ...ICE IM3 11 OPERATOR WEAR TEAR PARTS DIA NO PART NUMBER DESCRIPTION NO REQ D 1 6010135 5 Wheel 5 Wheel 2 ...