background image

Serious Connections

TM

ICCONS™ GAS TOOL GT-3 & GT-3ST USER MANUAL

4

the cartridge.

Transport

Transport of small amount in a private 
vehicle (<30kg) is permitted without 
a transport and safety sheet. The 
regulations by transport

Categories are:

   - Road/Rail: ADR – RID – UN code 1950 
class 2 code 5F
   - Sea: IMDG – UN code 1950 + risk 
sheet FD S-U
   - Air: IATA – UN code 1950 class 2.1
     Goods must be accompanied by a 
transport emergency card for road UN 
     1950 Transport by post is not 
permitted

Storage

   - Stores and showrooms must comply 
with building regulations. All local 
instructions corresponding to fire 
regulations must be followed.
   - Where possible, store fuel at stable 
temperature in the range: 5 to 25°C. Do 
not expose to temperatures exceeding 
50°C. Do not use a tool that emit flames, 
sparks or reach high temperatures in the 
vicinity that fuel cells are stored.
   - Do not store in designated 
thoroughfares, hallways or stairwells.
   - Stores in a well-ventilated area. Fuel 
cells must not be displayed in shop 
windows.
   - Storage with pyrotechnic products is 
not permitted.

First Aid

   - Direct contact with liquid gas may 
cause burns or frostbite.
   - In case of inhalation remove the 
person to fresh air, and encourage 
breathing. Should the casualty become 
unconscious, or breathing does not 
quickly return to normal, summon urgent 
medical assistance.

   - If gas gets into the eyes they should 
be flushed out with copious amounts of 
water. Skin contaminations should be 
removed with soapy water.
   - If symptoms persist, seek medical 
assistance.

C. THE USE OF BATTERY & CHARGING

SYSTEM

Introduction

The adaptor, charger and the battery 
are designed to operate together as one 
system. Only use the ‘ICCONS’ Adaptor 
& ‘ICCONS’ Charger for charging the 
‘ICCONS’ Batteries. The charging system 
is intended to be used in covered areas. 
Do not expose it to rain or to excessive 
humidity. 
Do not recharge non-rechargeable 
batteries.

Before charging

   - Arrange the adaptor output lead 
appropriately to avoid unnecessary 
damage, avoid laying output lead across 
walkway or doorway.
   - Check the system before use, if cable 
or plug damaged do not use for charging 
battery, and replace it immediately.
   - Keep the charger exhaust area clean 
and unblock to have the best cooling 
effect. Use dry cloth to clean the body 
and the contact of the charger or 
adaptor while it disconnected with the 
main power. 
   - Charge the battery in room 
temperature. If its temperature is 
less than 5°C or greater than 40°C 
will degrade the battery charging 
performance.
   - If the battery charger abnormally 
heats up or gives off fumes during 
charging, disconnect the charger and 
separate with the battery immediately. 
  

Содержание GT-3

Страница 1: ...USER MANUAL Serious Connections TM GT 3 GT 3ST GAS TOOL...

Страница 2: ...ecified by the manufacturer If the tool is weakened or damaged by Punching or engraving Modification not authorized by the manufacturer Guiding against templates made of hard material Dropping or push...

Страница 3: ...s Exhaust gases in a confined space can be hazardous Do not use the tool outside in the rain or where excessive moisture in present Keep the tool from heat sources as the pressurized fuel cell could b...

Страница 4: ...casualty become unconscious or breathing does not quickly return to normal summon urgent medical assistance If gas gets into the eyes they should be flushed out with copious amounts of water Skin cont...

Страница 5: ...r a long time Recharge it in each 3 months can help to compensate the self discharged and keep the battery in a good condition The charging systems should store at a place out of reach of children Chi...

Страница 6: ...Concrete 2 6mm Steel Plate to Hard Concrete 3 0mm step With changeable nose piece systems users are allowed to shoot for different purpose Please consult local agents for further details Only those f...

Страница 7: ...remain alight 5 After charging unplug the charger from the power source If both lights are blinking in same pace remove the battery cartridge and plug again If this happens continuously the battery ca...

Страница 8: ...r and create hazards to users and bystanders E Installing and removing fuel cell Caution Make sure the trigger is not held while inserting fuel cell Empty fasteners in the magazine before installing f...

Страница 9: ...amming of pins could be evident if users cannot drive the fasteners properly try following steps in subsequent order Caution Place the tool on flat surface prior to releasing the magazine magazine may...

Страница 10: ...ean the mesh with brush or air 3 Put the back cover on the machine and fasten with four screws NOTE Do not attempt to use water to clean the mesh The cover and mesh must be dry when operating the tool...

Страница 11: ...by Authorized Serviceman TROUBLESHOOTING Normal Stage Of Operation Possible reasons Services Battery is discharged Charge Battery Cell Possible reasons Services Battery is loose or contacts are bent...

Страница 12: ...not cycle fan runs Possible reasons Services Fuel Cell is empty Replace Fuel Cell Spark does not occur Contact authorized serviceman for repair SYMPTOM 4 Fail to drive fasteners Possible reasons Servi...

Страница 13: ...t stable SYMPTOM 4 Unstable performance Possible reasons Services Built up dirt and debris inside cylinder Contact authorized serviceman for repair SYMPTOM 5 Diminishing power Possible reasons Service...

Страница 14: ...Serious Connections TM ICCONS GAS TOOL GT 3 GT 3ST USER MANUAL 14 5 Parts List...

Страница 15: ...S TRACK ST short 25 NB1100 SOCKET SCREW Blue 242 81 NB1ZA0 FOLLOWER 26 NB1290 METAL WASHER 82 NB1910 TRACK CAP 27 NB1170 LOCKNUT 83 NB1800 TRACK CONNECTOR 28 NB1380 METAL WASHER 84 NB1160 SOCKET SCREW...

Страница 16: ...ong South Victoria 3175 Australia Passing on and duplication of this document exploitation and disclosure of its contents are forbidden unless expressly approved Violations render the offender liable...

Отзывы: