7.1.1.1
Electrodes Calibrating Procedure
At each meter, calibrate the holding and operating electrodes in one single procedure, as
described below:
Holding (middle) electrode:
Calibrate electrodes as follows:
1.
Carefully unlock the bottom clasp of the body and remove the lower cover with the
inner valve cylinder connected to it.
2.
Connect the 100Ω resistor between the Common (lower) and the holding (middle)
electrodes.
3.
Ensure that the meter is in wash mode (illuminated cleaning key indicator
).
4.
Press
to access electrode calibration mode.
AdJt
appears on the display panel.
5.
Press
.
H###
is displayed (
###
represents the calibration value). The range of calibration
values for Holding electrode is typically between
H112
and
H118
.
WARNING
Typically, calibration values displayed should be stable or vary
by only one digit. Out of range or unstable figures indicates an
electrical problem. Refer to the section “Searching for an
Electrical Problem,” for solving the problem.
6.
Press
again, to calibrate the Holding electrode and save the value.
AdJt
is displayed.
and