![ICAR VISIONS JH4AN-HD Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/icar-visions/jh4an-hd/jh4an-hd_manual_3325241023.webp)
AI MDVR Installation and debug manual
23
4.2
DSM parameter
Through the DSM parameter setting, the specified DSM alarm can be
configured. Such as closed eye alarm: alarm enable open/close, alarm
trigger speed, alarm high and low speed critical value, alarm duration,
alarm time gap, etc.
Image detection and rendering switch(ON/OFF)
:AI algorithm box is
displayed on the screen(ON)
,AI algorithm box is not displayed on the
screen(OFF).
Restore default: restore all algorithm parameters to factory defaults
Quick backup: back up the currently set algorithm parameters (backup to
the current phone)
Backup Review: view the parameter settings that have been backed up
Quick config: set the backup parameters to the current device (suitable
for batch setting calibration)