5.1Panel functions
Functions
Operation
mode
Display
Display
Temperature display
Drive cooling temperature display
Speed regulation mode
selection
0. Internal knob speed regulation
Parameter
setting
1. External analog speed regulation
2. Key speed regulation or 485 speed regulation
Speed setting
Step size is 100RPM; The set speed is lower than (400rpm/ pole
pairs) and the motor does not rotate
;
Direction setting
0. Motor stops
;
1.Enter the relevant menu through the panel key to set the forward
rotation
;
2.Enter the relevant menu through the panel keys, and set the reversal
3.Motor brakes
;
4.Direction port control.(F/R, EN
)
Reduction ratio setting
Set the speed ratio of the reducer
;
Alarm reset
Display the alarm code and press SET to reset the alarm
Polar number setting
Set the pole pairs of the adaptive motor (It is not recommended to
change the pole pairs during motor operation)
;
Under speed time setting
Set the under speed time. (E.g, set it as 5s, when the speed of the
motor is less than 50% of the set speed for over 5s, the motor will
stall.)
Maximum speed setting Set the upper limit of the speed (it is recommended to set it to the
maximum speed of the motor)
;
Acceleration and
deceleration time setting Set the ACC and DEC time through the panel keys
;
485 communication
address control
Select and control 485 communication address in steps of 1
;
485 communication rate
setting
Set the 485 communication rate in steps of 1
;
Port indication
Indicates the status of each IO port, read-only
;
Data initialization
Restore the operation data to the factory setting
;