preliminary
preliminary
iC-PZ AN1
GETTING STARTED GUIDE iC-PZ
Rev A1, Page 8/10
Automatic eccentricity adjustment (optional)
•
In tab ’Position Offset’ set
ST_OFF = ’0’ [ = 0x00] (iC-PZ revision Z only)
Figure 11: Offset
•
In tab ’Signal Conditioning’ section ’Eccentricity Ad-
justment’ set
AC_COUNT = ’0d04’ [ = 0x04]
AC_SEL1 = ’15 (default)’ [ = 0x0F]
AC_SEL2 = ’Best but longest auto-calibration’
[ = 0x00]
ECC_EN = ’0’ [ = 0x00]
•
Rotate at least at minimum speed required for the au-
tomatic eccentricity adjustment. The following value
is recommended:
Rotary (iC-PZ2656): 300 RPM
•
Send command AUTO_ADJ_ECC to execute auto-
calibration.
•
To enable eccentricity correction set
ECC_EN = ’1’ [ = 0x01]
Figure 12: Automatic eccentricity adjustment