Maintenance
The pressure regulator should be set at approximately 40 - 50 psi
(276 - 345 kPa). The regulator can only be set to a maximum of
60 psi (414 kPa). The door operates best at 40 psi (276 kPa).In
cold weather, seals may stiffen and require more air pressure for
proper operation. The pressure can be increased by lifting and
turning the adjustment knob (3) clockwise. Then press the cap
back down.
Opening Speed Adjustment
Loosen the locknut (4) and turn the opening speed screw (1)
clockwise to slow the door opening speed, or counterclockwise,
to increase the door opening speed. Tighten the locknut (4).
Closing Speed Adjustment
Loosen the locknut (4) and turn the closing speed screw (2)
clockwise to slow the door closing speed, or counterclockwise,
to increase the door closing speed. Tighten the locknut (4).
Electrically Actuated Entrance Door Adjustment
Electrically actuated doors are set to operate in 2 to 2 1/2
seconds. There is no adjustment for electrically actuated door
opening and closing speed.
Axles
Typical
Axle,
Tire,
and
Rim
Specifications-Vehicle
Identification Label
Front Axle – Inspection and Lubrication
Check to ensure that the front axle mounting U-bolts and nuts
are securely tightened.
Check front axle for damaged, binding, or worn parts, and
adequate lubrication.
•
Kingpin wear inspection requires that no weight is on the
tires.
192
Содержание CE Series 2020
Страница 4: ......
Страница 6: ......
Страница 14: ...Table of Contents viii ...
Страница 62: ...Instrumentation Declination Zone Map 48 ...
Страница 70: ...Instrumentation 56 ...
Страница 88: ...Driver Controls 74 ...
Страница 138: ...Climate Controls 124 ...
Страница 188: ...Roadside Emergencies Body Fuse Circuit Breaker Panel 174 ...
Страница 196: ...Roadside Emergencies 182 ...