Error
Code/Symptom
FRU/Action
165-XXX-000
(Failed
Service
Processor
test)
1.
System
Board.
Before
replacing
the
System
Board,
ensure
that
System
Board
jumper
J45
is
not
installed
(the
default)
when
the
error
occurs.
2.
Power
Backplane
3.
Hot-Swap
Drive
Backplane
180-XXX-000
(Diagnostics
LED
failure)
1.
Run
Diagnostic
LED
test
for
the
failing
LED.
2.
Power
Switch
Assembly
180-XXX-001
(Failed
information
LED
panel
test)
1.
Information
LED
Panel
2.
Diagnostic
LED
Panel
180-XXX-002
(Failed
Diagnostics
LED
Panel
test)
1.
Diagnostics
LED
Panel
2.
Power
Switch
Assembly
180-XXX-003
(Failed
System
Board
LED
test)
1.
System
Board
180-XXX-004
(Failed
Processor
Board
LED
test)
1.
System
Board
180-XXX-005
(Failed
SCSI
Backplane
LED
test)
1.
SCSI
Backplane
2.
SCSI
Backplane
Cable
3.
System
Board
180-XXX-006
(Memory
Board
LED
test)
1.
Memory
2.
System
Board
201-XXX-0NN
(Failed
Memory
test,
see
″
Memory
Settings
″
on
page
34.)
1.
DIMM
Location
DIMM1
-
DIMM4
where
NN
=
1
=
DIMM2,
2
=
DIMM1,
3
=
DIMM4,
4
=
DIMM3.
2.
System
Board
201-XXX-999
(Multiple
DIMM
failure,
see
error
text.)
1.
See
error
text
for
failing
DIMMs
2.
System
Board
202-XXX-001
(Failed
System
Cache
test)
1.
VRM
1
2.
Microprocessor
1
202-XXX-002
(Failed
System
Cache
test)
1.
VRM
2
2.
Microprocessor
2
206-XXX-000
(Failed
Diskette
Drive
test)
1.
Cable
2.
Diskette
Drive
3.
System
Board
215-XXX-000
(Failed
IDE
CD-ROM
test)
1.
CD-ROM
Drive
Cables
2.
CD-ROM
Drive
3.
System
Board
217-XXX-000
(Failed
BIOS
Fixed
Disk
test)
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Fixed
Disk
1
217-XXX-001
(Failed
BIOS
Fixed
Disk
test)
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Fixed
Disk
2
217-XXX-002
(Failed
BIOS
Fixed
Disk
test)
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Fixed
Disk
3
Symptom-to-FRU
index
131
Содержание xSeries 230 6RY
Страница 1: ...Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 2: ......
Страница 3: ...Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 20: ...12 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 38: ...30 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 48: ...40 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 126: ...118 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 132: ...124 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 167: ...Related service information 159...
Страница 168: ...160 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 169: ...Related service information 161...
Страница 170: ...162 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 171: ...Related service information 163...
Страница 172: ...164 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 173: ...Related service information 165...
Страница 174: ...166 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 184: ...176 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 185: ...Related service information 177...
Страница 186: ...178 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Страница 193: ......
Страница 194: ...Part Number 19K6112 Printed in USA 1P P N 19K6112...