8.
Inspect
the
power
supply
assemblies
and
check
that
the
fasteners
(screws
or
rivets)
in
the
cover
of
the
power-supply
unit
have
not
been
removed
or
disturbed.
9.
Before
connecting
the
SAN
Volume
Controller
to
the
SAN,
check
the
grounding.
External
machine
checks
Ensure
that
you
perform
an
external
machine
check
on
the
SAN
Volume
Controller.
Perform
the
following
external
machine
checks
before
you
install
the
SAN
Volume
Controller:
1.
Verify
that
all
external
covers
are
present
and
are
not
damaged.
2.
Ensure
that
all
latches
and
hinges
are
in
the
correct
operating
condition.
3.
If
the
SAN
Volume
Controller
is
not
installed
in
a
rack
cabinet,
check
for
loose
or
broken
feet.
4.
Check
the
power
cord
for
damage.
5.
Check
the
external
signal
cable
for
damage.
6.
Check
the
cover
for
sharp
edges,
damage,
or
alterations
that
expose
the
internal
parts
of
the
device.
7.
Correct
any
problems
that
you
find.
Internal
machine
checks
Ensure
that
you
perform
an
internal
machine
check
before
installing
the
SAN
Volume
Controller.
Perform
the
following
internal
machine
checks
before
you
install
the
SAN
Volume
Controller:
1.
Check
for
any
non-IBM
changes
that
might
have
been
made
to
the
machine.
If
any
are
present,
obtain
the
″
Non-IBM
Alteration
Attachment
Survey
″
form
number
R009,
from
the
IBM
branch
office.
Complete
the
form
and
return
it
to
the
branch
office.
2.
Check
the
condition
of
the
inside
of
the
machine
for
any
metal
or
other
contaminants,
or
any
indications
of
water,
other
fluid,
fire,
or
smoke
damage.
3.
Check
for
any
obvious
mechanical
problems,
such
as
loose
components.
4.
Check
any
exposed
cables
and
connectors
for
wear,
cracks,
or
pinching.
Inspecting
the
uninterruptible
power
supply
for
unsafe
conditions
Ensure
that
you
take
the
time
to
inspect
the
uninterruptible
power
supply
(UPS)
for
unsafe
conditions.
Consider
the
following
conditions
and
the
safety
hazards
they
present:
Electrical
hazards
(especially
primary
power)
Primary
voltage
on
the
frame
can
cause
serious
or
lethal
electrical
shock.
Explosive
hazards
A
bulging
capacitor
can
cause
serious
injury.
Mechanical
hazards
Loose
or
missing
items
(for
example,
nuts
and
screws)
can
cause
serious
injury.
Be
cautious
of
potential
safety
hazards
that
are
not
covered
in
the
safety
checks.
If
unsafe
conditions
are
present,
determine
how
serious
the
hazards
are
and
whether
you
should
continue
before
correcting
the
problem.
xx
IBM
TotalStorage
SAN
Volume
Controller:
Installation
Guide
Содержание TotalStorage SAN Volume Controller
Страница 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 2 1 0 SC26 7541 04...
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 2 1 0 SC26 7541 04...
Страница 8: ...vi IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 10: ...viii IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 11: ...Tables 1 Uninterruptible power supply support guidelines 17 Copyright IBM Corp 2003 2005 ix...
Страница 12: ...x IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 30: ...xxviii IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 44: ...14 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 62: ...32 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 102: ...72 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 108: ...78 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 114: ...84 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 121: ......
Страница 122: ...Part Number 64P8289 Printed in USA SC26 7541 04 1P P N 64P8289...
Страница 123: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 2 1 0...