Table 9. POST error messages (continued)
POST message
Description
I9990650
AC power has been restored.
Action: No action is required. This message appears each time AC power is restored to the
appliance after an AC power loss.
Other Numbers
POST found an error.
Action: Follow the instructions on the screen.
Event/error logs
The POST error log contains the three most recent error codes and messages that
the system generated during POST. The System Event/Error Log contains all error
messages issued during POST and all system status messages from the Netfinity
Advanced System Management Processor.
To view the contents of the error logs, start the Configuration/Setup Utility program;
then, selectEvent/Error Logsfrom the main menu.
POST diagnostic programs
The appliance diagnostic programs are stored in upgradable read-only memory
(ROM) on the system board. These programs are the primary method of testing the
major components of your appliance.
Diagnostic program error messages indicate that a problem exists; they are not
intended to be used to identify a failing part. Troubleshooting and servicing of
complex problems that are indicated by error messages should be performed by
trained service personnel.
Sometimes the first error to occur causes additional errors. In this case, the
appliance displays more than one error message. Always follow the suggested
action instructions for the first error message that appears.
The following sections contain the error codes that might appear in the detailed test
log and summary log when running the diagnostic programs.
The error code format is as follows:
fff-ttt-iii-date-cc-text message
where:
fff
is the three-digit function code that indicates the function being tested when
the error occurred. For example, function code 089 is for the
microprocessor.
ttt
is the three-digit failure code that indicates the exact test failure that was
encountered. (These codes are for trained service personnel and are
described in the Hardware Maintenance Manual.)
iii
is the three-digit device ID. (These codes are for trained service personnel
and are described in the Hardware Maintenance Manual.)
date
is the date that the diagnostic test was run and the error recorded.
cc
is the check digit that is used to verify the validity of the information.
62
300G User’s Reference
Содержание TotalStorage Network Attached Storage 300G
Страница 1: ...TotalStorage Network Attached Storage 300G User s Reference V ersion 1 Release 1 GA27 4271 00...
Страница 2: ......
Страница 3: ...TotalStorage Network Attached Storage 300G User s Reference V ersion 1 Release 1 GA27 4271 00...
Страница 8: ...vi 300G User s Reference...
Страница 10: ...viii 300G User s Reference...
Страница 14: ...2 300G User s Reference...
Страница 32: ...20 300G User s Reference...
Страница 38: ...26 300G User s Reference...
Страница 62: ...50 300G User s Reference...
Страница 85: ......