Replacing
the
drives
one
at
a
time
Use
this
procedure
to
replace
all
the
drives
one
at
a
time.
You
cannot
use
this
procedure
on
RAID
0
logical
drives
(use
the
procedure
in
Note:
If
your
storage
subsystem
has
hot
spares
assigned,
you
might
want
to
unassign
the
hot
spares
while
you
perform
this
procedure.
If
you
do
not,
reconstruction
might
start
on
the
hot
spare
before
you
insert
the
new
drive.
The
data
on
the
new
drive
is
still
rebuilt,
but
the
process
takes
longer
for
each
drive.
Remember
to
reassign
the
hot
spares
when
you
are
finished
with
this
procedure.
To
replace
the
drives
one
at
a
time,
perform
the
following
steps:
1.
Read
the
following
information:
v
particularly
the
paragraphs
that
discuss
the
differences
between
the
two
possible
upgrade
procedures
v
Your
software
documentation
regarding
drive
upgrades
and
installation
v
The
documentation
that
comes
with
the
new
drives
Read
all
precautionary
notes,
kit
instructions,
and
other
information.
Kit
instructions
often
contain
the
most
current
information
regarding
the
drives
and
their
installation,
plus
upgrade
or
servicing
procedures.
Compare
the
kit
instructions
with
this
procedure
to
determine
if
you
need
to
modify
this
procedure.
2.
Use
the
Storage
Manager
client
to
check
the
status
of
the
unit.
Correct
any
problems
that
are
reported.
3.
Back
up
the
data
on
the
drives
that
you
are
replacing.
Attention:
When
you
handle
static-sensitive
devices,
take
precautions
to
avoid
damage
from
static
electricity.
For
details
about
handling
static-sensitive
devices,
see
4.
Unpack
the
new
drives.
Set
the
drives
on
a
dry,
level
surface
away
from
magnetic
fields.
Save
the
packing
material
and
documentation
in
case
you
need
to
return
the
drives.
5.
Use
the
storage
management
software
to
ensure
that
the
array
that
was
defined
using
these
drives
is
in
optimal
(not
degraded)
state
before
manually
failing
the
first
drive
you
want
to
replace.
If
the
array
is
in
degraded
state,
use
the
recovery
procedures
to
bring
the
array
into
the
optimal
state.
Make
sure
that:
v
You
fail
only
one
drive
v
The
software
status
display
shows
a
failed
status
for
the
appropriate
drive
v
The
amber
Drive
fault
LED
(on
the
front
bezel
below
the
drive)
is
on
Attention:
Removing
the
wrong
drive
can
cause
data
loss.
Make
sure
that
you
remove
only
the
failed
drive
CRU.
The
Drive
fault
LED
below
the
failed
drive
CRU
should
be
on.
If
you
remove
an
active
drive
accidentally,
wait
at
least
30
seconds
and
then
reinstall
it.
Because
you
failed
two
drives
in
a
RAID
array,
the
array
might
be
marked
failed
by
the
controller.
This
array
will
not
be
available
to
the
host
for
I/O.
See
the
Storage
Manager
client
for
further
recovery
instructions.
Do
not
attempt
to
replace
any
drives
until
the
array
is
brought
back
to
optimal
state.
76
IBM
TotalStorage
FAStT100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Содержание totalstorage fastt100
Страница 1: ...IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide GC26 7641 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide GC26 7641 00 ...
Страница 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Страница 159: ......
Страница 160: ... Part Number 24P8970 Printed in USA GC26 7641 00 1P P N 24P8970 ...