a05m0383
Figure 84: Ferrite beads on the cable assembly
3. Connect the Ethernet and power connectors.
4. Route the cable as shown in Figure 83 on page 255 and fasten the hook-and-loop fasteners.
5. Replace the top cover and screw it down with four screws.
6. Insert the enclosure into the rack. See “Removing the enclosure from a rack” on page 258.
7. Install the drive canisters. See “FID 85: Drive canister” on page 252 for the procedure for removing
and replacing a drive canister.
Removing the Rack Mount Card (RMC)
The Rack Mount Card (RMC) allows both power supplies to share the load to the two drive canisters. If
one power supply fails, the RMC selects the remaining power supply to provide power to both drive
canisters. This card can be removed and replaced, if needed.
1. Complete “Preparing the tape drive for service” on page 183, then return here.
2. Remove the drives. See “FID 85: Drive canister” on page 252
3. Remove the enclosure from the rack. See “Removing the enclosure from a rack” on page 258.
4. Remove both cables. See “FID EA: Cables FRU kit” on page 255.
5. Remove power supplies. See “FID 82: Power supply” on page 252.
6. Turn the enclosure upside down.
7. Remove the four screws that secure the power supply bracket. See Figure 85 on page 257.
256 IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information