1.
With
both
levers
rotated
out
perpendicular
to
the
face
of
the
component,
slide
the
back
of
the
component
into
the
appropriate
slot.
2.
Push
the
component
into
the
slot
and,
when
the
component
is
almost
fully
installed,
verify
that
the
notches
in
both
levers
are
aligned
with
the
pins
on
the
storage
subsystem.
Verify
this
alignment
to
ensure
that
the
component
is
pulled
evenly
into
the
storage
subsystem,
ensuring
full
electrical
connection
contact
on
all
interface
pins.
3.
Press
the
component
fully
into
the
slot,
engaging
the
pins
on
the
storage
subsystem.
4.
Hold
open
both
latches
and
rotate
both
levers
simultaneously
to
the
closed
position.
Release
the
latches.
When
you
release
the
latches,
you
should
hear
both
latches
snap
over
the
levers.
This
indicates
that
the
component
is
locked
in
place.
Replacing
a
controller
Attention:
Before
you
replace
a
RAID
controller,
verify
the
following:
v
The
replacement
RAID
controller
part
number
matches
the
part
number
of
the
RAID
controller
to
be
replaced.
To
provide
full
functionality,
the
two
controllers
should
have
the
same
memory
capacity.
Although
two
controllers
of
different
memories
can
be
paired
in
an
storage
subsystem,
the
mismatch
causes
some
functions
to
be
disabled
(for
example,
the
cache
mirroring
function).
v
Inserting
a
DS4800
model
80A/H
controller
into
a
non-model
80A/H
DS4800
subsystems
(that
is,
model
82A/H,
model
84A/H,
model
88A/H)
will
result
in
the
controller
to
be
held
in
lockdown
state.
Similarly,
inserting
a
non-model
80
DS4800
controller
into
a
DS4800
model
80
subsystem
will
cause
it
to
be
held
in
lock
down
state.
v
Both
power
supply
and
fan
units
must
be
connected
and
powered
on
with
no
lighted
Needs
Attention
LEDs.
Ensure
that
the
Power
LEDs
on
each
of
the
power
supply
and
fan
units
are
lit.
If
either
of
the
power
supply
and
fan
units
is
not
optimal,
it
is
recommended
that
you
replace
that
component
before
you
proceed
with
the
controller
replacement
procedure.
v
If
you
are
replacing
an
optimal
controller,
first
make
sure
that
the
other
RAID
controller
is
optimal
and
that
the
fibre
channel
path
from
the
hosts
to
the
other
RAID
controller
is
also
optimal.
Use
the
following
procedure
to
replace
a
controller
in
an
DS4800
Storage
Subsystem.
Attention:
If
you
are
upgrading
controllers
you
received
through
an
upgrade
kit,
refer
to
and
use
the
instructions
provided
in
the
upgrade
kit
to
replace
the
controllers
instead
of
the
instructions
in
this
section.
Each
RAID
controller
has
a
unique
hardware
Ethernet
address,
which
is
printed
on
a
label
on
the
front.
1.
Use
the
DS4000
Storage
Manager
client
software
to
a
storage
subsystem
profile.
Move
logical
drive
ownership
to
the
other
controller.
If
the
controller
you
are
replacing
has
failed
but
is
still
operating,
move
the
failed
controller
to
an
Offline
state.
Attention:
Never
remove
a
controller
unless
the
Service
Action
Allowed
status
LED
is
turned
on.
Doing
so
can
result
in
a
potential
loss
of
data.
2.
Locate
the
failed
controller
by
checking
the
Needs
Attention
status
LEDs
on
the
controllers
in
the
storage
subsystem.
shows
the
Chapter
5.
Replacing
components
145
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...