automatically
turn
on.
Before
the
interconnect-battery
unit
Service
Action
Allowed
status
LED
can
turn
on,
you
must
use
the
DS4000
Storage
Manager
client
to
place
controller
B
offline.
(Controller
A
is
the
controller
designated
to
receive
all
I/O
activity
when
the
interconnect-battery
unit
is
removed
from
the
DS4800.)
By
placing
controller
B
offline,
you
route
all
controller
and
I/O
activity
through
controller
A.
This
maintains
data
availability
while
the
interconnect-battery
unit
is
removed,
preventing
any
problems
that
would
normally
arise
from
the
loss
of
communication
between
controllers
A
and
B.
Attention:
Before
you
remove
the
interconnect-battery
unit,
you
must
verify
that
controller
A
is
in
an
optimal
state,
and
the
power
supply
and
fan
unit
CRU
that
is
connected
to
controller
A
(the
right
power
supply)
is
optimal.
Never
remove
the
interconnect-battery
unit
when
controller
A
or
the
power
supply
and
fan
unit
CRUs
are
not
in
an
optimal
state.
Multiple
component
failures
When
multiple
components
in
the
DS4800
have
failed,
the
behavior
of
the
Service
Action
Allowed
and
Needs
Attention
LEDs
can
vary
from
situation
to
situation.
In
some
cases,
multiple
Service
Action
Allowed
status
LEDs
light
when
their
corresponding
Needs
Attention
LEDs
are
lit.
In
other
cases,
none
of
the
Service
Action
Allowed
status
LEDs
light
when
their
corresponding
Needs
Attention
LEDs
are
lit.
This
variance
exists
because
the
ability
to
remove
a
component
depends
on
the
different
data
availability
dependencies
of
the
storage
subsystem
components.
If
replacing
any
one
of
the
multiple
components
that
have
their
Needs
Attention
LEDs
lit
will
cause
the
DS4800
Storage
Subsystem
to
shut
down,
the
Service
Action
Allowed
status
LEDs
will
not
light
on
any
of
the
components
that
need
attention.
For
example,
if
both
the
right
power
supply
and
fan
unit
(which
is
linked
to
controller
A)
and
controller
B
need
attention,
then
neither
of
the
Service
Action
Allowed
status
LEDs
on
these
components
would
light.
Removing
the
controller
B
before
replacing
the
failed
right
power
supply
and
fan
unit
would
cause
controller
A
to
lose
power,
resulting
in
a
loss
of
data
availability.
(This
linkage
exists
because
the
power
distribution
from
each
power
supply
and
fan
unit
runs
through
the
controller
physically
connected
to
that
power
supply
and
fan
unit.)
However,
if
replacing
any
one
of
the
multiple
components
that
have
their
Needs
Attention
LEDs
lit
will
not
cause
the
DS4800
Storage
Subsystem
to
shut
down,
then
the
Service
Action
Allowed
status
LEDs
will
light
on
all
of
the
components
that
need
attention.
For
example,
if
the
right
power
supply
and
fan
unit
(which
is
linked
to
controller
A)
and
controller
A
both
need
attention,
then
the
Service
Action
Allowed
status
LEDs
on
both
of
these
components
would
light,
indicating
that
either
component
can
be
replaced
first.
Important:
In
this
situation
(in
which
replacing
any
one
of
the
multiple
components
that
have
their
Needs
Attention
LEDs
lit
will
not
cause
the
DS4800
Storage
Subsystem
to
shut
down),
after
you
remove
one
failed
component,
the
Service
Action
Allowed
status
LEDs
on
the
remaining
components
that
need
attention
might
turn
off.
This
change
in
the
Service
Action
Allowed
status
LEDs
indicates
that
removing
additional
components
now
might
cause
the
storage
subsystem
to
shut
down.
For
example,
if
both
power
supply
and
fan
units
have
failed,
the
Needs
Attention
and
the
Service
Action
Allowed
status
LEDs
would
be
lit
for
both
components.
However,
when
you
remove
one
power
supply
and
fan
unit
from
the
system,
the
Service
Action
Allowed
status
LED
on
the
remaining
power
supply
and
fan
unit
turns
off,
indicating
that
you
now
Chapter
5.
Replacing
components
143
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...