v
Do
not
leave
the
device
where
others
can
handle
and
possibly
damage
the
device.
v
While
the
device
is
still
in
its
static-protective
package,
touch
it
to
an
unpainted
metal
part
of
the
storage
subsystem
for
at
least
two
seconds.
This
drains
static
electricity
from
the
package
and
from
your
body.
v
Remove
the
device
from
its
package
and
install
it
directly
into
your
storage
subsystem
without
setting
it
down.
If
it
is
necessary
to
set
the
device
down,
place
it
in
its
static-protective
package.
Do
not
place
the
device
on
your
storage
subsystem
cover
or
any
metal
surface.
v
Take
additional
care
when
handling
devices
during
cold
weather
because
heating
reduces
indoor
humidity
and
increases
static
electricity.
Service
Action
Allowed
status
LED
Each
controller,
power
supply
and
fan
unit,
and
interconnect-battery
unit
has
a
blue
Service
Action
Allowed
status
LED.
The
purpose
of
the
Service
Action
Allowed
status
LED
is
to
help
ensure
that
a
component
is
not
removed
before
it
is
safe
to
do
so.
Do
not
remove
any
DS4800
component
unless
the
component’s
Service
Action
Allowed
status
LED
is
lit.
Attention
Never
remove
a
controller,
power
supply
and
fan
unit,
or
interconnect-battery
unit
unless
the
Service
Action
Allowed
status
LED
is
turned
on.
Doing
so
can
result
in
a
potential
loss
of
data.
If
the
Needs
Attention
LED
is
lit
and
the
associated
Service
Action
Allowed
status
LED
is
not
lit,
then
you
must
perform
additional
diagnostics
before
you
can
remove
the
indicated
component.
Use
the
Recovery
Guru
instructions
in
the
DS4000
Storage
Manager
Subsystem
Management
window
or
refer
to
the
appropriate
component
replacement
instructions
in
this
chapter
for
the
additional
diagnostics
required
in
this
case.
The
Service
Action
Allowed
status
LED
automatically
turns
on
or
off
as
conditions
change.
Wait
at
least
two
minutes
after
you
replace
each
component
for
the
controller
to
recognize
the
new
component
and
update
the
LED
status.
In
most
cases
when
a
single
component
fails,
the
Service
Action
Allowed
status
LED
turns
on
steadily
when
the
Needs
Attention
status
LED
is
turned
on
for
the
component.
The
following
sections
discuss
the
behavior
of
the
Service
Action
Allowed
status
LED
in
cases
of
single
and
multiple
component
failures.
Single
component
failures
When
a
single
component
in
the
DS4800
has
failed,
the
following
list
indicates
the
behavior
of
the
Service
Action
Allowed
status
LED
lights:
v
If
a
controller
or
power
supply
and
fan
unit
fails
and
needs
to
be
replaced,
the
amber
Needs
Attention
status
LED
on
that
component
turns
on
to
indicate
that
a
service
action
is
required.
If
there
are
no
data
availability
dependencies
or
other
conditions
that
dictate
that
the
component
should
not
be
removed,
the
blue
Service
Action
Allowed
status
LED
turns
on.
Do
not
remove
any
components
other
than
the
component
indicated
by
the
lit
blue
Service
Action
Allowed
status
LED.
v
The
interconnect-battery
unit
contains
the
mid-plane
that
communicates
between
controllers
A
and
B
in
the
DS4800
Storage
Subsystem.
If
the
interconnect-battery
unit
needs
to
be
replaced,
the
Service
Action
Allowed
status
LED
does
not
142
IBM
System
Storage
DS4800
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...