v
Make
sure
that
the
device
drivers
on
the
client
and
server
are
using
the
same
protocol.
If
the
Ethernet
controller
still
cannot
connect
to
the
network
but
the
hardware
appears
to
be
working,
the
network
administrator
must
investigate
other
possible
causes
of
the
error.
Solving
undetermined
problems
If
the
diagnostic
tests
did
not
diagnose
the
failure
or
if
the
server
is
inoperative,
use
the
information
in
this
section.
If
you
suspect
that
a
software
problem
is
causing
failures
(continuous
or
intermittent),
see
Damaged
data
in
CMOS
memory
or
damaged
BIOS
code
can
cause
undetermined
problems.
To
reset
the
CMOS
data,
use
the
password
override
jumper
to
override
the
power-on
password
and
clear
the
CMOS
memory;
see
If
you
suspect
that
the
BIOS
code
is
damaged,
see
Damaged
memory
card
connector
pins
or
improperly
installed
memory
cards
can
prevent
the
server
from
starting
or
might
cause
a
POST
checkpoint
halt.
For
example,
a
memory
card
that
is
not
completely
installed
or
has
bent
connector
pins
might
cause
the
server
to
continually
restart
or
display
an
F2
checkpoint
halt.
Remove
and
inspect
all
memory
card
connector
pins
for
bent
or
damaged
interface
pins.
Replace
all
memory
cards
that
have
damaged
pins
and
ensure
that
the
card
is
completely
latched
into
place.
Check
the
LEDs
on
all
the
power
supplies
(see
If
the
LEDs
indicate
that
the
power
supplies
are
working
correctly,
complete
the
following
steps:
1.
Turn
off
the
server.
2.
Make
sure
that
the
server
is
cabled
correctly.
3.
Remove
or
disconnect
the
following
devices,
one
at
a
time,
until
you
find
the
failure.
Turn
on
the
server
and
reconfigure
it
each
time.
v
Any
external
devices.
v
Surge-suppressor
device
(on
the
server).
v
Modem,
printer,
mouse,
and
non-IBM
devices.
v
Each
adapter.
v
Hard
disk
drives.
v
Memory
modules.
The
minimum
configuration
requirement
is
2
GB
(two
1
GB
DIMMs).
v
Service
processor.
The
following
minimum
configuration
is
required
for
the
server
to
turn
on:
v
One
microprocessor
v
Two
1
GB
DIMMs
on
the
memory
card
v
One
power
supply
v
Power
backplane
v
Power
cord
v
I/O
board
v
PCI-X
board
4.
Turn
on
the
server.
If
the
problem
remains,
suspect
the
following
components
in
the
following
order:
a.
Power
backplane
106
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide
Содержание System x3950
Страница 1: ...IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 124: ...108 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 132: ...116 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 189: ......
Страница 190: ...Part Number 31R1886 Printed in USA 1P P N 31R1886...