The following sections provide instructions for starting the LSI Logic Configuration
Utility program and performing selected functions.
Starting the LSI Logic Configuration Utility program
To start the LSI Logic Configuration Utility program, complete the following steps:
1. Turn on the server.
2. When the prompt
<<< Press <CTRL><C> to start LSI Logic Configuration
Utility >>>
is displayed, press Ctrl+C. If you have set an administrator
password, you are prompted to type the password.
3. To select a controller (channel) from the list of adapters, use the arrow keys and
press Enter.
4. To change the settings of the selected items, follow the instructions on the
screen. If you select
Device Properties
or
Mirroring Properties
, additional
screens are displayed.
When you have finished changing settings, press Esc to exit from the program;
select
Save
to save the settings that you have changed.
Formatting a SCSI hard disk drive
Low-level formatting removes all data from the hard disk. If there is data on the disk
that you want to save, back up the hard disk before you perform this procedure.
Note:
Before you format a SCSI hard disk, make sure that the disk is not part of a
mirrored pair. From the list of adapters, select the controller (channel) for the
drive that you want to format. Select
Mirroring Properties
and make sure
that the mirroring value for the drive is
None
.
To format a drive, complete the following steps:
1. From the list of adapters, select the controller (channel) for the drive that you
want to format.
2. Select
Device Properties
.
3. To highlight the drive that you want to format, use the Up Arrow and Down
Arrow keys. To scroll left and right, use the Left Arrow and Right Arrow keys or
the End key.
4. To start the low-level formatting operation, select
Format
and press Enter .
Creating a mirrored pair of SCSI hard disk drives
To create a mirrored pair of SCSI hard disk drives, complete the following steps:
1. From the list of adapters, select the controller (channel) for the drives that you
want to mirror.
2. Select
Mirroring Properties
.
3. Use the arrow keys to highlight the first drive in the pair; then, press the Minus
key to change the mirroring value to
Primary
.
4. Use the arrow keys to highlight the second drive in the pair; then, press the
Minus key to change the mirroring value to
Secondary
.
5. To establish a third drive that will take over the function of either mirrored drive
in the event of a failure, use the arrow keys to highlight the drive that you want
to use for that purpose; then, press the Minus key to change the mirroring value
to
Hot Spare
.
224
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...