Installing an adapter in the system-board tray
To install a PCIe adapter in the system-board tray, complete the following steps.
1. Touch the static-protective package that contains the adapter to any
unpainted
metal surface on the outside of the system-board tray; then, remove the adapter
from the package. Avoid touching the components and gold-edge connectors on
the adapter.
2. See the documentation that comes with the adapter to determine whether you
must set any jumpers or switches.
3. Align the adapter with the PCIe slot on the riser-card assembly; then, press the
adapter into the slot.
Notes:
a. Ensure that the tab on the riser-card bracket is properly aligned with the slot
on the adapter bracket.
b. Make sure that the adapter is inserted carefully. Improper installation of an
adapter might damage the PCIe riser-card assembly or the adapter.
4. Pinch the two sides of the PCIe riser-card assembly as indicated in above
graphic and insert the PCIe riser-card assembly with the adapter into the
riser-card slot, evenly with both hands, on the system board. Then, install the
retaining screw.
5. If you disconnected cables when you removed the adapter, reconnect the
cables.
6. Install the storage enclosure, if you removed one (see “Installing an expansion
enclosure on a system-board tray” on page 132); otherwise, install the
system-board tray cover (see “Installing the system-board tray cover” on page
125).
7. Install the system-board tray in the chassis (see “Installing the system-board
tray in a 2U chassis” on page 127 or “Installing the system-board tray in a 3U
chassis” on page 129).
Note:
To complete the installation of the PCIe adapter, see the documentation
that comes with the adapter for device-driver and configuration
information.
154
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...