v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 3, “Parts listing,” on page 59 to determine which components are customer replaceable units (CRU) and
which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Message
number Component
Test
State Description Action
201-802-xxx
Memory
Memory Test
Aborted
Test canceled: the
end address in
the E820 function
is less than 16
MB.
1. Turn off and restart the system-board
tray.
2. Run the test again.
3. Make sure that all DIMMs are enabled
in the BIOS configuration utility program
(press F1 at system startup).
4. Make sure that the BIOS code is at the
latest level. The installed firmware level
is shown in the DSA event log in the
Firmware/VPD section for this
component. For the latest level of
firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
5. Run the test again.
6. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
201-803-xxx Memory
Memory
Test
Aborted Test
canceled:
could not enable
the processor
cache.
1. Turn off and restart the system-board
tray.
2. Run the test again.
3. Make sure that the BIOS code is at the
latest level. The installed firmware level
is shown in the DSA event log in the
Firmware/VPD section for this
component. For the latest level of
firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
4. Run the test again.
5. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
Chapter 2. Diagnostics
37
Содержание System x iDataPlex dx340
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx340 Types 6385 6386 6389 7831 7832 and 7834 Problem Determination and Service Guide...
Страница 180: ...164 System x iDataPlex dx340 Types 6385 6386 6389 7831 7832 and 7834 Problem Determination and Service Guide...
Страница 195: ......
Страница 196: ...Part Number 90Y5677 Printed in USA 1P P N 90Y5677...