Starting code update...
==================================================================
ptupgrade V3.3.84.0 package
kernel
2.6.18-238.40.1.e15.x86_64
PT Build
7133.084
==================================================================
Extracting perl modules...
job 76 at 2012-12-05 09:59
job 77 at 2012-12-05 09:59
Going to start installation GUI process
Checking for available packages:
[ Done ]
There are some old packages:
1. /install/PT_MD5_TS7620_12TB_V3.3.90.0-full.x86_64.tar (node 1)
Which packages do you want to delete ? (give numbers with comma between them,
for example 1,3,4 or 0/enter for none): 1
Deleting packages
[ Done ]
Package /install/PT_MD5_TS7620_12TB_V3.3.90.0-full.x86_64.tar (node 1) deleted
Upgrade candidates:
1. /mnt/cdrom/PT_MD5_TS7620_12TB_V3.3.90.0-full.x86_64.tar (node 1)
2. /mnt/cdrom/PT_MD5_TS7620_23TB_V3.3.90.0-full.x86_64.tar (node 1)
Which Package do you want to install ? (press ’q’ to quit) : 2
Extracting new GUI package from upgrade package
[ Done ]
Checking prerequisites conditions for package
[ Done ]
Going to upgrade to package /mnt/cdrom/PT_MD5_TS7620_23TB_V3.3.90.0-full.x86_64.tar
(build=7133.086, version=3, release=3, minor=86, fix=0)
Upgrade method = SEQUENTIAL
Do you want to continue ? (yes|no) yes
Calling Upgrade Process
[ Done ]
Upgrade called successfully
5.
When the restart is complete, the increased capacity is installed.
Important:
Following the restart, certain conditions might cause the bottom
LED on all 12 HDDs to illuminate as solid amber. If this situation occurs, stop
what you are doing and contact IBM support for assistance. See “Getting help
by telephone” on page 2, for instructions.
Configure the increased capacity
Before you begin
Allow the server to restart so that all services are running before you configure the
increased capacity.
Procedure
To configure the increased capacity:
1.
Log in to the ProtecTIER Service menu with user name
ptconfig
and
password
ptconfig
. The ProtecTIER Service menu opens.
Chapter 2. Prerequisites
9
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Содержание System Storage ProtecTIER TS7620
Страница 4: ...iv Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Страница 44: ...40 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Страница 52: ...48 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Страница 54: ...50 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Страница 57: ......
Страница 58: ... Part Number 39U3474 Printed in USA GA32 2222 03 1P P N 39U3474 ...